Development of a three‐dimensional dose evaluation method for computed tomography

Author:

Katsuda Toshizo1ORCID,Gotanda Rumi2,Gotanda Tatsuhiro2,Kuwano Tadao3,Tanki Nobuyoshi4,Yabunaka Kouichi5

Affiliation:

1. Medical radiation technology Shizuoka College of Medicalcare Science Hamamatsu‐city Shizuoka Japan

2. Faculty of Health Science and Technology Kawasaki University of Medical Welfare Okayama Japan

3. Department of Radiology Osaka Center for Cancer and Cardiovascular Diseases Prevention Jyoto‐ku Osaka Japan

4. Brain Activity Imaging Center ATR‐Promotions Inc Seika‐cho Kyoto Japan

5. Department of Ultrasound Ono Memorial Hospital Nishiku Osaka Japan

Abstract

AbstractDuring a single scan using computed tomography, an X‐ray tube orbits along a 360°‐circular path around the patient. A scan obtained using the half‐cylindrical type phantoms with a radiochromic film sandwiched in between reveals a pixel value map illustrating the two‐dimensional (2D) dose distribution. A three‐dimensional (3D) dose distribution can be obtained with a 360° rotation of the 2D dose map. This study evaluates the concept and methodology of creating a 3D dose map to develop a phantom with a radiochromic film for obtaining the 3D dose distribution. The coronal and axial plane dose distributions were also evaluated. A single scan computed tomography image obtained using a half‐cylindrical type of acrylic phantom with a sandwiched radiochromic film was studied. The diameters of the phantoms were 10 and 16 cm, and their lengths were 30 cm. A 2D image of the XR‐QA2 film was obtained using an image scanner and image processing software. A red channel image was used to obtain the 3D dose distribution using a computing platform. A pseudo color was applied to the red channel image from which cross‐sectional color images were obtained. Half of the cross‐sectional pixel data were rotated by 360° to generate the data for each axial plane. The image created was saved, and a 3D pixel value map was constructed. The dose measurement procedure for the 3D dose distribution was developed using half‐cylindrical acrylic phantoms with a radiochromic film.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献