Narrow beam breast CT: proof‐of‐concept

Author:

Ghazi Peymon1,Fu Guanhao2,Ghazi Tara1,Kazanzides Peter2,Iordachita Iulian2

Affiliation:

1. Malcova Inc. Newark California USA

2. Johns Hopkins University Baltimore Maryland USA

Abstract

AbstractBackgroundIn breast CT, scattered photons form a large portion of the acquired signal, adversely impacting image quality throughout the frequency response of the imaging system. Prior studies provided evidence for a new image acquisition design, dubbed Narrow Beam Breast CT (NB‐bCT), in preventing scatter acquisition.PurposeHere, we report the design, implementation, and initial characterization of the first NB‐bCT prototype.MethodsThe imaging system's apparatus is composed of two primary assemblies: a dynamic Fluence Modulator (collimator) and a photon‐counting line detector. The design of the assemblies enables them to operate in lockstep during image acquisition, converting sourced x‐rays into a moving narrow beam. During a projection, this narrow beam sweeps the entire fan angle coverage of the imaging system. The assemblies are each comprised of a metal housing, a sensory system, and a robotic system. A controller unit handles their relative movements. To study the impact of fluence modulation on the signal received in the detector, three physical breast phantoms, representative of small, average, and large size breasts, were developed and imaged, and acquired projections analyzed. The scatter acquisition in each projection as a function of breast phantom size was investigated. The imaging system's spatial resolution at the center and periphery of the field of view was measured.ResultsMinimal acquisition of scattered rays occurs during image acquisition with NB‐bCT; results in minimal scatter to primary ratios in small, average, and large breast phantoms imaged were 0.05, 0.07, and 0.9, respectively. System spatial resolution of 5.2 lp/mm at 10% max MTF and 2.9 lp/mm at 50% max MTF at the center of the field of view was achieved, with minimal loss with the shift toward the corner (5.0 lp/mm at 10% max MTF and 2.5 lp/mm at 50% max MTF).ConclusionThe disclosed development, implementation, and characterization of a physical NB‐bCT prototype system demonstrates a new method of CT‐based image acquisition that yields high spatial resolution while minimizing scatter‐components in acquired projections. This methodology holds promise for high‐resolution CT‐imaging applications in which reduction of scatter contamination is desirable.

Publisher

Wiley

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3