Influence of maternal characteristics and gestational age on hemodynamic indices: NICOM device‐specific reference ranges

Author:

Perry H.12ORCID,Stirrup O.3,Gutierrez J.12,Vinayagam D.12ORCID,Thilaganathan B.12ORCID,Khalil A.12ORCID

Affiliation:

1. Vascular Biology Research Centre, Molecular and Clinical Sciences Research Institute St George's University of London London UK

2. Fetal Medicine Unit St George's University Hospitals NHS Foundation Trust, University of London London UK

3. Centre for Clinical Research in Infection and Sexual Health, Institute for Global Health University College London London UK

Abstract

ABSTRACTObjectivesTo construct reference ranges for stroke volume, cardiac output and systemic vascular resistance (SVR) in normal pregnancy for the NICOM® device, and to explore associations between maternal characteristics and these hemodynamic variables.MethodsThis was a prospective cohort study of healthy singleton pregnancies between 10 and 40 weeks' gestation attending a tertiary referral hospital between September 2012 and May 2018. Measurements of stroke volume, cardiac output and SVR were obtained throughout pregnancy using NICOM, a non‐invasive device based on bioreactance technology. NICOM device‐specific reference ranges were created with respect to gestational age and maternal characteristics. Once the distribution of the data had been determined with respect to the gestational age, patient characteristics were added to the model to test whether they provided a significant improvement in prediction of the median value. The effect was assessed of maternal weight, height, smoking status, conception using assisted reproductive technology, nulliparity and ethnicity.ResultsWe included 411 women in this study. The relationships between cardiac variables and gestational age observed in the NICOM‐specific reference ranges are consistent with previous findings, with increasing cardiac output values until around 35 weeks and a decrease thereafter until term, and decreasing SVR until around 36 weeks, followed by an increase towards 40 weeks. Stroke volume showed a small linear increase across gestation with lower variability in observations close to term. Maternal weight, height and age were associated with cardiac output (all P < 0.05) and SVR (all P < 0.01), whilst maternal weight and height were associated with stroke volume (both P < 0.001). Ethnicity was significantly associated with stroke volume (P = 0.001) but not with cardiac output or SVR.ConclusionsThis study presents device‐specific reference ranges for stroke volume, cardiac output and SVR for the NICOM device in healthy pregnancy and describes the maternal characteristics that are associated with the values of these hemodynamic measurements. Studies using NICOM in pregnancy can use these ranges in order to evaluate observations relative to those expected in uncomplicated pregnancy conditional on maternal characteristics. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.

Funder

National Institute for Health Research

King's College Hospital NHS Foundation Trust

Publisher

Wiley

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.7亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2025 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3