Comprehensive wood dwelling tests for Post‐and‐Beam and Shear‐Wall structures reflecting foundation boundaries

Author:

Takaya Kazuki1ORCID,Ota Kazuto1,Yenidogan Cem2,Takahashi Takehiro3,Yamada Shohei4,Kashiwa Hisatoshi5,Kawamata Yosuke6,Hayashi Kazuhiro7,Nagae Takuya8ORCID

Affiliation:

1. Graduate School of Environmental Studies Nagoya University Nagoya‐shi Aichi‐ken Japan

2. Department of Civil Engineering Yildiz Technical University Istanbul Turkey

3. ICHIJO Co., Ltd. Shizuoka Japan

4. NIKKEN SEKKEI Ltd. Tokyo Japan

5. Graduate School of Engineering Osaka University Osaka Japan

6. National Research Institute for Earth Science and Disaster Resilience (NIED) Ibaraki Japan

7. Graduate School of Engineering Chiba University Chiba Japan

8. Disaster Mitigation Research Center Nagoya University Nagoya‐shi Aichi‐ken Japan

Abstract

AbstractThis paper focuses on the ultimate state of three‐story wood dwellings with high aspect ratios, which are increasing in Japan's urban areas. Using shaking table test results from the 2019 full‐scale shaking table test, a comprehensive study is conducted on the accuracy of evaluating ultimate state through the story shear failure mode at the first story, the tension fracture mode at the wall base of the first story, and foundation sliding mode on the soil. Methods evaluating the dynamic response behaviors of the building systems are also investigated. In the test, the current Japanese seismic design guidelines were applied, and two Grade‐3 buildings were prepared. One adopted the Post‐and‐Beam structure (A‐building), and the other the Shear‐Wall structure (B‐building). A series of tests planned very different physical boundary conditions surrounding their reinforced concrete (RC) mat foundations. The sills, column bases and wall bases of the upper wood structures were anchored to the RC foundations by steel anchor bolts, according to the current Allowable Stress Design (ASD) requirements. In the first stage, A‐building equipped a Base‐Isolation system, while B‐building represented a generic foundation constructed on a 1.5 m‐height real soil ground by preparing a rigid soil box (Foundation‐Soil system). In the second stage of A‐building and B‐building, the foundation was firmly fixed (Fixed‐Foundation system), and shaking table motions were fully applied to the foundations. The entire test system was setup on the large shaking table facility at E‐Defense, and a series of tests were conducted using JMA‐Kobe motion and JR‐Takatori motion recorded in the 1995 Kobe earthquake as Maximum‐Considered‐Earthquake motions. Confirmed was the change in the structural mechanism due to the upper structural systems and the foundation boundaries. Regarding the upper wood structure performance in the Fixed‐Foundation system, a story shear failure mode was observed at the first story in A‐building, while a tension fracture mode at the base of the first story in B‐building. This difference of failure mode is difficult to determine with ASD. The maximum strength were more than four times higher than the ASD base shear force. Tension fracture capacity at the wall base was mainly enhanced by the presence of the steel anchor bolts. Regarding the foundation performance in Foundation‐Soil system of B‐building, a horizontal displacement up to 240 mm was observed between the foundation and soil when JMA‐Kobe 100% was applied. A response reduction effect was observed in the upper wood structure, similar to the Base‐Isolation system of A‐building. The initial friction and cyclic friction strength capacities between the foundation and soil were quantitatively evaluated considering the horizontal two‐directional sliding. The representative test results were converted to the corresponding SDOF systems based on the first mode response assessment. In the Fixed‐Foundation system, the dynamic response characteristics of the upper wood structures were properly represented using Ibarra‐Medina‐Krawinkler pinching model in the equivalent SDOF system.

Publisher

Wiley

Reference30 articles.

1. Full-scale cyclic test of a Japanese post and beam wood shearwall assembly

2. A study on hysteresis characteristics of full‐scale wooden houses based on shaking table test;Katsuhiko K;J Struct Eng B [in Japanese],2001

3. STUDY ON SEISMIC PERFORMANCE OF WOOD-FRAMED RESIDENTIAL STRUCTURES BY FULL-SCALE TEST

4. MiyakeT MinowaC IsodaH KoshiharaM TsuchimotoT SakamotoI.Collapsing response analyses of existing wood houses corresponding to shaking table test.10th World Conference on Timber Engineering.Miyazaki Japan June 2‐5  2008;1:1770‐1777.

5. Design methods and shaking table tests on 3‐story wood houses by post and beam construction part 1: outline of series of test;Naohito K;AIJ Conv [in Japanese],2010

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3