Geometric and dosimetric evaluation of deep learning based auto‐segmentation for clinical target volume on breast cancer

Author:

Zhong Yang1234,Guo Ying1234,Fang Yingtao1234,Wu Zhiqiang1234,Wang Jiazhou1234,Hu Weigang1234

Affiliation:

1. Department of Radiation Oncology Fudan University Shanghai Cancer Center Shanghai China

2. Department of Oncology, Shanghai Medical College Fudan University Shanghai China

3. Shanghai Clinical Research Center for Radiation Oncology Shanghai China

4. Shanghai Key Laboratory of Radiation Oncology Shanghai China

Abstract

AbstractBackgroundRecently, target auto‐segmentation techniques based on deep learning (DL) have shown promising results. However, inaccurate target delineation will directly affect the treatment planning dose distribution and the effect of subsequent radiotherapy work. Evaluation based on geometric metrics alone may not be sufficient for target delineation accuracy assessment. The purpose of this paper is to validate the performance of automatic segmentation with dosimetric metrics and try to construct new evaluation geometric metrics to comprehensively understand the dose‐response relationship from the perspective of clinical application.Materials and MethodsA DL‐based target segmentation model was developed by using 186 manual delineation modified radical mastectomy breast cancer cases. The resulting DL model were used to generate alternative target contours in a new set of 48 patients. The Auto‐plan was reoptimized to ensure the same optimized parameters as the reference Manual‐plan. To assess the dosimetric impact of target auto‐segmentation, not only common geometric metrics but also new spatial parameters with distance and relative volume () to target were used. Correlations were performed using Spearman's correlation between segmentation evaluation metrics and dosimetric changes.ResultsOnly strong (|R2| > 0.6, p < 0.01) or moderate (|R2| > 0.4, p < 0.01) Pearson correlation was established between the traditional geometric metric and three dosimetric evaluation indices to target (conformity index, homogeneity index, and mean dose). For organs at risk (OARs), inferior or no significant relationship was found between geometric parameters and dosimetric differences. Furthermore, we found that OARs dose distribution was affected by boundary error of target segmentation instead of distance and to target.ConclusionsCurrent geometric metrics could reflect a certain degree of dose effect of target variation. To find target contour variations that do lead to OARs dosimetry changes, clinically oriented metrics that more accurately reflect how segmentation quality affects dosimetry should be constructed.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3