Implementation of superficial radiation therapy (SRT) using SRT‐100 Vision™ for non‐melanoma skin cancer in a Radiation Oncology clinic

Author:

Lee Yongsook C.12,Davis Stephen D.12,Romaguera William1,Chaswal Vibha12,Tolakanahalli Ranjini12,Gutierrez Alonso N.12,Kalman Noah S.12

Affiliation:

1. Department of Radiation Oncology Miami Cancer Institute Baptist Health South Florida Miami Florida USA

2. Department of Radiation Oncology Herbert Wertheim College of Medicine Florida International University Miami Florida USA

Abstract

AbstractPurposeThis article describes our experience in implementation of superficial radiation therapy (SRT) using SRT‐100 Vision™ for non‐melanoma skin cancer.MethodsFollowing the American Association of Physicists in Medicine Task Group‐61 protocol, absolute output (absorbed dose to water at surface (cGy/min)) was measured for three energies (50, 70, and 100 kV) and for six applicators (1.5–5.0 cm in diameter). Percent depth dose (PDD) and profiles were also measured. Timer testing and ultrasound testing were performed. A treatment time calculation worksheet was created. Quality assurance (QA) of SRT‐100 Vision was implemented. After treatment workflow for our clinic was developed, end‐to‐end (E2E) testing was performed using a Rando phantom. Considerations for treatment using SRT‐100 Vision were made.ResultsAbsolute output (cGy/min) decreases as energy increases and applicator size decreases. Due to scatter from the applicator, PDD at depths ≤5 mm does not follow conventional trends but PDD at depths ≥15 mm increases with increasing applicator size. Profiles for the 5 cm applicator do not have strong dependence on depth except profiles at 5 mm for 50 kV. Timer/end errors are negligible for all three energies. Ultrasound images confirm allowed field of view and depth as well as no image artifacts and spatial integrity. Daily, monthly and annual QA of SRT‐100 Vision implemented in our clinic is listed in a table format. E2E testing results (<1%) demonstrate the functionality and performance of our treatment workflow. Our considerations for SRT treatment include patient, applicator size and energy selections, patient setup, and shields.ConclusionsThis article is expected to serve as guidance for Radiation Oncology and/or Dermatology clinics aspiring to initiate an SRT program in their clinics.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3