Determination of therapeutic threshold in sacral nerve modulation for faecal incontinence

Author:

Koch S M P1,van Gemert W G1,Baeten C G M I1

Affiliation:

1. Department of Surgery, University Hospital Maastricht, Maastricht, The Netherlands

Abstract

Abstract Background The aim of the study was to determine the therapeutic stimulation threshold in patients with successful sacral nerve modulation for faecal incontinence. Methods Patients who had undergone successful permanent sacral nerve modulator implantation and had been followed up for a minimum of 3 months were included. The sensitivity threshold and motor threshold were determined and correlated with therapeutic response. Patients went home with the stimulator set at 0·6 V below the sensitivity threshold. Each week the voltage was increased by 0·2 V until the sensitivity threshold was reached. The effects on anorectal physiology and continence were recorded. Results Eight patients (seven women) with a median age of 58·5 years were included. The median follow-up was 6·3 months. The median sensibility threshold volume of rectal sensation was 50 ml, the median urge threshold volume was 140 ml and the median maximum tolerated rectal volume 240 ml. The median number of incontinence episodes and days per week affected by incontinence decreased from 5·0 and 3·8 before operation to 0·7 and 0·7 respectively after follow-up for 3 months. At anorectal manometry the median resting and stimulation anal canal pressures were 57 and 85 mmHg respectively, and remained constant over time. The therapeutic response threshold was significantly lower than the sensitivity threshold (median 1·6 versus 1·7 V; P = 0·042). The median motor threshold was 2·1 V, significantly higher than the sensitivity threshold (P = 0·009). The stimulation threshold for suboptimal therapeutic response was 1·4 V. In five of the eight patients the therapeutic response threshold was the same as the sensitivity threshold. Conclusion Sacral nerve modulation can produce a therapeutic effect below the sensitivity threshold. A lower stimulation voltage increases the lifespan of the pulse generator.

Publisher

Oxford University Press (OUP)

Subject

Surgery

Cited by 46 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3