Study on the Consistency Between Automatic Measurement Based on Convolutional Neural Network Technology and Manual Visual Evaluation in Intracavitary Ultrasonic Cine of Anterior Pelvic

Author:

Wei Ni‐ya1ORCID,Li Xiao‐kun1,Lu Xi‐duo23,Liu Xin‐ting1,Sun Rui‐jie1,Wang Yue1ORCID

Affiliation:

1. Department of Ultrasound Peking University Shenzhen Hospital Shenzhen China

2. National‐Regional Key Technology Engineering Laboratory for Medical Ultrasound Shenzhen University Shenzhen China

3. Shenzhen RayShape Medical Technology Co., Ltd Shenzhen China

Abstract

ObjectivesThis study was to evaluate the application of automatic measurement based on convolutional neural network (CNN) technology in intracavitary ultrasound cine of anterior pelvic.MethodsA total of 500 patients who underwent pelvic floor ultrasound examination at Peking University Shenzhen Hospital from July 2021 to February 2022 were retrospectively retrieved by the picture archiving and communication system (PACS) system, and 300 cases were used as a training set. The training set was labeled by three experienced ultrasound physicians to train CNN models and develop an automatic measurement software. The remaining 200 cases were used as a test set. Automatic measurement software identified relevant anatomical structures frame by frame and determined the two frames with the greatest difference, calculated the bladder neck descent (BND), urethral rotation angle (URA), and retrovesical angle (RA). Meanwhile, two experienced ultrasound physicians evaluated the resting frame and the maximum Valsalva frame on the cines by manual visual evaluation, labeled the anatomical structures in the corresponding frame, such as the inferoposterior margin of pubic symphysis, the mid‐axis of pubic symphysis, bladder contour, and urethra in the front, and calculated BND, URA, and RA. Considering that the residual urine volume (RUV) in the bladder may affect the results, enrolled patients were grouped according to the RUV (10–50 mL, 50–100 mL, and >100 mL). The consistency of the results by automatic measurement and manual visual evaluation was evaluated using the intraclass correlation coefficient (ICC) and the Bland–Altman graph.ResultsOf the 200 cases in the test set, 120 cases were successfully identified by the CNN automatic software with a 60% recognition rate. In the case of successful identification, the ICC of manual visual evaluation measurement and automatic measurement was 0.936 (BND), 0.911 (URA), 0.756 (RA in rest), and 0.877 (RA at maximum Valsalva), respectively. In addition, the RUV had a negligible effect on the consistency. The Bland–Altman plot shows the proportion of samples outside the limit was below 5%.ConclusionsCNN‐based automatic measurement software exhibited high reliability in anterior pelvic measurement, which results in a significantly enhanced measurement efficiency.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3