A reusable 3D printed brain‐like phantom for benchmarking electrical properties tomography reconstructions

Author:

Meerbothe T. G.12ORCID,Florczak S.3,van den Berg C. A. T.12ORCID,Levato R.34ORCID,Mandija S.12ORCID

Affiliation:

1. Department of Radiotherapy, Division of Imaging and Oncology University Medical Center Utrecht Utrecht The Netherlands

2. Computational Imaging Group for MR Therapy and Diagnostics, Center for Image Sciences University Medical Center Utrecht Utrecht The Netherlands

3. Department of Orthopaedics, University Medical Center Utrecht Utrecht University Utrecht The Netherlands

4. Department of Clinical Sciences, Faculty of Veterinary Medicine Utrecht University Utrecht The Netherlands

Abstract

AbstractPurposeIn MR electrical properties tomography (MR‐EPT), electrical properties (EPs, conductivity and permittivity) are reconstructed from MR measurements. Phantom measurements are important to characterize the performance of MR‐EPT reconstruction methods, since they allow knowledge of reference EPs values. To assess reconstruction methods in a more realistic scenario, it is important to test the methods using phantoms with realistic shapes, internal structures, and dielectric properties. In this work, we present a 3D printing procedure for the creation of realistic brain‐like phantoms to benchmark MR‐EPT reconstructions.MethodsWe created two brain‐like geometries with three different compartments using 3D printing. The first geometry was filled once, while the second geometry was filled three times with different saline‐gelatin solutions, resulting in a total of four phantoms with different EPs. The saline solutions were characterized using a probe. 3D MR‐EPT reconstructions were performed from MR measurements at 3T. The reconstructed conductivity values were compared to reference values of the saline‐gelatin solutions. The measured fields were also compared to simulated fields using the same phantom geometry and electrical properties.ResultsThe measured fields were consistent with simulated fields. Reconstructed conductivity values were consistent with the reference (probe) conductivity values. This indicated the suitability of such phantoms for benchmarking MR‐EPT reconstructions.ConclusionWe presented a new workflow to 3D print realistic brain‐like phantoms in an easy and affordable way. These phantoms are suitable to benchmark MR‐EPT reconstructions, but can also be used for benchmarking other quantitative MR methods.

Funder

Nederlandse Organisatie voor Wetenschappelijk Onderzoek

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3