Clinical reference dosimetry for the 0.5 T inline rotating biplanar Linac‐MR

Author:

Yip Eugene12,Tari Shima Y12,Reynolds Michael W23,Sinn David24,Murray Brad R5,Fallone B Gino125,Oliver Patricia AK126

Affiliation:

1. Department of Oncology Medical Physics Division University of Alberta Edmonton Alberta Canada

2. Department of Medical Physics Cross Cancer Institute Edmonton Alberta Canada

3. Department of Radiation Oncology BC Cancer ‐ Victoria Victoria British Columbia Canada

4. Department of Radiaiton Oncology The Queen's Medical Centre Honolulu Hawaii USA

5. MagnetTx Oncology Solutions Edmonton Alberta Canada

6. Department of Medical Physics Nova Scotia Health Halifax Nova Scotia Canada

Abstract

AbstractBackgroundThe world's first clinical 0.5 T inline rotating biplanar Linac‐MR system is commissioned for clinical use. For reference dosimetry, unique features to device, including an SAD = 120 cm, bore clearance of 60 cm × 110 cm, as well as 0.5 T inline magnetic field, provide some challenges to applying a standard dosimetry protocol (i.e., TG‐51).PurposeIn this work, we propose a simple and practical clinical reference dosimetry protocol for the 0.5T biplanar Linac‐MR and validated its results.MethodsOur dosimetry protocol for this system is as follows: tissue phantom ratios at 20 and 10 cm are first measured and converted into %dd10x beam quality specifier using equations provided and Kalach and Rogers. The converted %dd10x is used to determine the ion chamber correction factor, using the equations in the TG‐51 addendum for the Exradin A12 farmer chamber used, which is cross‐calibrated with one calibrated at a standards laboratory. For a 0.5 T parallel field, magnetic field effect on chamber response is assumed to have no effect and is not explicitly corrected for. Once the ion chamber correction factor for a non‐standard SAD (kQ,msr) is determined, TG‐51 is performed to obtain dose at a depth of 10 cm at SAD = 120 cm. The dosimetry protocol is repeated with the magnetic field ramped down.To validate our dosimetry protocol, Monte Carlo (EGSnrc) simulations are performed to confirm the determined kQ,msr values. MC Simulations and magnetic Field On versus Field Off measurements are performed to confirm that the magnetic field has no effect. To validate our overall dosimetry protocol, external dose audits, based on optical simulated luminescent dosimeters, thermal luminescent dosimeters, and alanine dosimeters are performed on the 0.5 T Linac‐MR system.ResultsOur EGSnrc results confirm our protocol‐determined kQ,msr values, as well as our assumptions about magnetic field effects (kB = 1) within statistical uncertainty for the A‐12 chamber. Our external dosimetry procedures also validated our overall dosimetry protocol for the 0.5 T biplanar Linac‐MR hybrid. Ramping down the magnetic field has resulted in a dosimetric difference of 0.1%, well within experimental uncertainty.ConclusionWith the 0.5 T parallel magnetic field having minimal effect on the ion chamber response, a TPR20,10 approach to determine beam quality provides an accurate method to perform clinical dosimetry for the 0.5 T biplanar Linac‐MR.

Publisher

Wiley

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3