Comparison of surface freshwater PFAS sampling methods to evaluate potential for bias due to PFAS enrichment in the surface microlayer

Author:

Roark Shaun A.1ORCID,Wilson‐Fallon Alexander2ORCID,Struse Amanda3ORCID,Rectenwald Heather4ORCID,Bogdan Dorin5,Heron Chris67ORCID,Field Jennifer7ORCID

Affiliation:

1. Jacobs Greenwood Village Colorado USA

2. Jacobs Sacramento California USA

3. Jacobs Sioux Falls South Dakota USA

4. Jacobs Honolulu Hawaii USA

5. AECOM Grand Rapids Michigan USA

6. Jacobs Corvallis Oregon USA

7. Department of Environmental and Molecular Toxicology Oregon State University Corvallis Oregon USA

Abstract

AbstractPer‐ and polyfluoroalkyl substances (PFAS) accumulate at the air–water interface of the surface microlayer (SML) on marine and freshwater bodies. In order to determine if including the SML when sampling bulk surface water leads to a high bias in measured PFAS concentrations, a pilot study and a full field study were conducted. The pilot study conducted at two sites was aimed at determining the analytical precision and small‐scale (~1 m) spatial variability in concentrations of PFAS in bulk water and the SML. The full field study was performed at 11 sites, where three commonly used bulk surface water sampling methods were compared: (1) a peristaltic pump with tubing that excludes the SML, (2) a fully submerged sample bottle that excludes the SML, and (3) a partially submerged sample bottle that allows inclusion of the SML. The SML was sampled using the glass plate method. The samples were analyzed by liquid chromatography tandem mass spectrometry. The pilot study indicated that sampling variation was greater than analytical variation (although Levene's tests indicated that the differences were not statistically significant) and that relatively small differences in the mean concentration among sampling methods could be detected. The full investigation indicated that there was no evidence of high bias of PFAS concentrations in bulk surface water resulting from inclusion of SML using the partially submerged bottle sampling method. Unexpectedly, there was evidence that samples collected using the partially submerged bottle had slightly lower PFAS concentrations, particularly for less hydrophobic PFAS, than bulk water samples that excluded the SML. Additionally, the PFAS enrichment factor in the SML increased with increasing retention time, although the increase was not evident at all sampling sites for all PFAS. Integr Environ Assess Manag 2024;1–12. © 2024 SETAC

Funder

Strategic Environmental Research and Development Program

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3