Echo time optimization for in‐vivo measurement of unsaturated lipid resonances using J‐difference‐edited MRS

Author:

Lin Dingyi1ORCID,Zhou Jiaqiang2,Cao Yang1,Wang Ziyan1,Hsu Yi‐Cheng3,Zheng Fenping2,Li Hong2,Sun Shuiya2,Ren Hong4,Deng Liping4,Chen Feng5,Wang Min12ORCID

Affiliation:

1. College of Biomedical Engineering and Instrument Science Zhejiang University Hangzhou Zhejiang China

2. School of Medicine, Sir Run Run Shaw Hospital, Department of Endocrinology Zhejiang University Hangzhou Zhejiang China

3. MR Collaboration Siemens Healthineers Itd Shanghai China

4. School of Medicine, Department of Radiology Sir Run Run Shaw Hospital, Zhejiang University Hangzhou Zhejiang China

5. School of Medicine, the First Affiliated Hospital, Department of Radiology Zhejiang University Hangzhou Zhejiang China

Abstract

AbstractPurposeMeasuring lipid composition provides more information than just total lipid content. Hence, the non‐invasive measurement of unsaturated lipid protons with both high efficiency and precision is of pressing need. This study was to optimize echo time (TE) for the best resolving of J‐difference editing of unsaturated lipid resonances.MethodsThe TE dependence of J‐difference‐edited (JDE) MRS was verified in the density‐matrix simulation, soybean oil phantom, in‐vivo experiments of white adipose tissue (WAT), and skeletal muscles using single‐voxel MEGA‐PRESS sequence at 3T. The peak SNRs and Cramér‐Rao lower bounds (CRLBs) acquired at the proposed TE of 45 ms and previously published TE of 70 ms were compared (eight pairs) in WAT, extramyocelluar lipids (EMCLs), and intramyocellular lipids (IMCLs). The lipid composition in skeletal muscles was compared between healthy males (n = 7) and females (n = 7).ResultsThe optimal TE was suggested as 45 ms. Compared to 70 ms, the mean signal gains at TE of 45 ms were 151% in WAT, 168% in EMCL, 204% in IMCL for allylic resonance, and 52% in EMCL for diallylic resonance. CRLBs were significantly reduced at TE of 45 ms in WAT, EMCL, IMCL for allylic resonance and in EMCL for diallylic resonance. With TE of 45 ms, significant gender differences were found in the lipid composition in EMCL pools, while no difference in IMCL pools.ConclusionThe JDE‐MRS protocol with TE of 45 ms allows improved quantification of unsaturated lipid resonances in vivo and future lipid metabolism investigations.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3