Vitamin E‐stabilized polyethylene shows similar survival rates at minimum 7‐year follow‐up compared to conventional polyethylene in primary total knee arthroplasty

Author:

Bistolfi Alessandro1ORCID,Spezia Marco2,Cipolla Alessandra3ORCID,Bonera Monica3,Mellano Danilo2,Banci Lorenzo4ORCID,Colombo Marta4ORCID,Massè Alessandro35ORCID

Affiliation:

1. Orthopaedics and Traumatology Cardinal Massaia Asti Hospital Asti Italy

2. Centro Ortopedico Quadrante Hospital Omegna Italy

3. University of the Studies of Turin Turin Italy

4. Clinical Research Department Permedica Orthopaedics Merate Italy

5. Department of Orthopaedics and Traumatology CTO AOU Città della Salute e della Scienza di Torino Turin Italy

Abstract

AbstractPurposeThe aim of this cross‐sectional study was to compare survival, clinical and radiographic results of total knee arthroplasty (TKA) with vitamin E‐stabilized polyethylene (VEPE) or conventional polyethylene (CPE) at a minimum of 7‐year follow‐up.MethodsPatients who underwent primary TKA between 2011 and 2015, receiving the same cemented rotating platform knee design with VEPE or CPE tibial inserts, were identified. Patients were contacted for clinical and radiographic follow‐up. American Knee Society Score (KSS), Forgotten Joint Score (FJS‐12), presence of periprosthetic radiolucent lines (RLLs) and osteolysis were evaluated at the last follow‐up. Any revision, reintervention or other complications were recorded.ResultsAmong 350 TKAs initially identified, 102 VEPE and 97 CPE knees were included for analysis with mean follow‐up of 8.5 and 8.3 years, respectively. No significant difference was found in survival rates at 10‐year follow‐up with revision due to aseptic loosening (95.0% vs. 97.8%, p = 0.29) or due to any reason (87.6% vs. 89.6%, p = 0.78) between VEPE and CPE TKA. KSS function score resulted significantly higher in the VEPE group over CPE (77 vs. 63, p = 0.01). RLLs were more frequent in VEPE than CPE (54% vs. 32%, p = 0.05), mainly noticed medially and posteriorly beneath the tibial plate, adjacent to the trochlear shield and the posterior condyles. Osteolysis was observed in one knee per group, but patients were asymptomatic with stable implants.ConclusionTKA with VEPE and CPE tibial inserts showed comparable survival rates, complications and clinical and radiographic results up to 10‐year follow‐up.Level of EvidenceLevel III.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3