Arteriosclerosis Assessment Based on Single‐Point Fingertip Pulse Monitoring Using a Wearable Iontronic Sensor

Author:

Huang Yi1,Zhao Lingyu2,Cai Minkun2,Zhu Jiaqi2,Wang Liu3,Chen Xinxing4,Zeng Yumin5,Zhang Liqing6,Shi Jidong7,Guo Chuan Fei2ORCID

Affiliation:

1. Department of Cardiology Southern University of Science and Technology Hospital (SUSTech‐Hospital) Shenzhen 518071 China

2. Department of Materials Science and Engineering Southern University of Science and Technology Shenzhen 518055 China

3. CAS Key Laboratory of Mechanical Behavior and Design of Materials Department of Modern Mechanics University of Science and Technology of China Hefei 230026 China

4. Shenzhen Key Laboratory of Biomimetic Robotics and Intelligent Systems Guangdong Provincial Key Laboratory of Human‐Augmentation and Rehabilitation Robotics in Universities Southern University of Science and Technology Shenzhen 518055 China

5. Department of Sports Center Southern University of Science and Technology Shenzhen 518055 China

6. Department of Endocrinology Southern University of Science and Technology Hospital (SUSTech‐hospital) Shenzhen 518071 China

7. Shenzhen Key Laboratory of Ultraintense Laser and Advanced Material Technology Center for Advanced Material Diagnostic Technology College of Engineering Physics Shenzhen Technology University Shenzhen 518118 China

Abstract

AbstractArteriosclerosis, which appears as a hardened and narrowed artery with plaque buildup, is the primary cause of various cardiovascular diseases such as stroke. Arteriosclerosis is often evaluated by clinically measuring the pulse wave velocity (PWV) using a two‐point approach that requires bulky medical equipment and a skilled operator. Although wearable photoplethysmographic sensors for PWV monitoring are developed in recent years, likewise, this technique is often based on two‐point measurement, and the signal can easily be interfered with by natural light. Herein, a single‐point strategy is reported based on stable fingertip pulse monitoring using a flexible iontronic pressure sensor for heart‐fingertip PWV (hfPWV) measurement. The iontronic sensor exhibits a high pressure‐resolution on the order of 0.1 Pa over a wide linearity range, allowing the capture of characteristic peaks of fingertip pulse waves. The forward and reflected waves of the pulse are extracted and the time difference between the two waves is computed for hfPWV measurement using Hiroshi's method. Furthermore, a hfPWV‐based model is established for arteriosclerosis evaluation with an accuracy comparable to that of existing clinical criteria, and the validity of the model is verified clinically. The work provides a reliable technique that can be used in wearable arteriosclerosis assessment systems.

Funder

National Natural Science Foundation of China

Natural Science Foundation of Guangdong Province

Publisher

Wiley

Subject

Pharmaceutical Science,Biomedical Engineering,Biomaterials

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3