AbstractBackgroundEncountering a retained root tip post‐extraction and prior to implant placement is a possible clinical complication. There are numerous approaches for removing retained roots that may be traumatic or atraumatic. Regardless of the approach, careful treatment planning is important to minimize complications, reduce morbidity, and preserve bony structures. The aim of the current case study is to introduce a technique and digitally generated device used for identifying and atraumatically removing a retained root tip and simultaneously placing a stable dental implant.MethodsA 63‐year‐old female with a history of myocardial infarction, hypertension, and acute pancreatitis presented for implant placement at site #5. Clinical examination revealed adequate interocclusal, mesiodistal, and buccolingual dimensions for implant placement. Radiographic examination using cone beam computed tomography revealed that retained root #5 interfered with implant placement. Digital planning was used to extract the root tip with minimal trauma to maintain adequate bone for simultaneous implant placement with good primary stability.ResultsThe follow‐ups at 1, 3, and 6 weeks and 4, 8, and 10 months revealed good bone preservation with an osseointegrated implant.ConclusionsEmployment of digital planning to create a palatal window allowed excellent accuracy in removing the retained root while maintaining the bony foundation for a well osseointegrated dental implant.Key points Pre‐planning using cone beam computed tomography scan merged with an intraoral digital scan is necessary for precise location of a retained root and correct implant placement with excellent primary stability. A digitally planned 3D surgical guide is a useful method for extracting retained roots during implant placement to minimize bone damage. Digital planning provides a precise and minimally invasive implant surgery.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3