Feasibility study of photon‐counting CT for material identification based on YSO/SiPM detector: A proof of concept

Author:

Zhang Du1,Wu Bin2,Xi Daoming2,Chen Rui3,Xiao Peng124,Xie Qingguo124

Affiliation:

1. Department of Electronic Engineering and Information Science University of Science and Technology of China Hefei China

2. Institute of Artificial Intelligence Hefei Comprehensive National Science Center Hefei China

3. The Raymeasure Medical Technology Co., Ltd Suzhou China

4. Wuhan National Laboratory for Optoelectronics Wuhan China

Abstract

AbstractBackgroundCurrent photon‐counting computed tomography (CT) systems utilize semiconductor detectors, such as cadmium telluride (CdTe), cadmium zinc telluride (CZT), and silicon (Si), which convert x‐ray photons directly into charge pulses. An alternative approach is indirect detection, which involves Yttrium Orthosilicate (YSO) scintillators coupled with silicon photomultipliers (SiPMs). This presents an attractive and cost‐effective option due to its low cost, high detection efficiency, low dark count rate, and high sensor gain.ObjectiveThis study aims to establish a comprehensive quantitative imaging framework for three‐energy‐bin proof‐of‐concept photon‐counting CT based on YSO/SiPM detectors developed in our group using multi‐voltage threshold (MVT) digitizers and assess the feasibility of this spectral CT for material identification.MethodsWe developed a proof‐of‐concept YSO/SiPM‐based benchtop spectral CT system and established a pipeline for three‐energy‐bin photon‐counting CT projection‐domain processing. The empirical A‐table method was employed for basis material decomposition, and the quantitative imaging performance of the spectral CT system was assessed. This evaluation included the synthesis errors of virtual monoenergetic images, electron density images, effective atomic number images, and linear attenuation coefficient curves. The validity of employing A‐table methods for material identification in three‐energy‐bin spectral CT was confirmed through both simulations and experimental studies.ResultsIn both noise‐free and noisy simulations, the thickness estimation experiments and quantitative imaging results demonstrated high accuracy. In the thickness estimation experiment using the practical spectral CT system, the mean absolute error for the estimated thickness of the decomposed Al basis material was 0.014 ± 0.010 mm, with a mean relative error of 0.66% ± 0.42%. Similarly, for the decomposed polymethyl methacrylate (PMMA) basis material, the mean absolute error in thickness estimation was 0.064 ± 0.058 mm, with a mean relative error of 0.70% ± 0.38%. Additionally, employing the equivalent thickness of the basis material allowed for accurate synthesis of 70 keV virtual monoenergetic images (relative error 1.85% ± 1.26%), electron density (relative error 1.81% ± 0.97%), and effective atomic number (relative error 2.64% ± 1.26%) of the tested materials. In addition, the average synthesis error of the linear attenuation coefficient curves in the energy range from 40 to 150 keV was 1.89% ± 1.07%.ConclusionsBoth simulation and experimental results demonstrate the accurate generation of 70 keV virtual monoenergetic images, electron density, and effective atomic number images using the A‐table method. Quantitative imaging results indicate that the YSO/SiPM‐based photon‐counting detector is capable of accurately reconstructing virtual monoenergetic images, electron density images, effective atomic number images, and linear attenuation coefficient curves, thereby achieving precise material identification.

Funder

National Natural Science Foundation of China

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3