Case series of catheter‐based arrhythmia ablation in 13 pregnant women

Author:

Mladoniczky Sára1ORCID,Nagy Zsófia1,Földesi Csaba1,Som Zoltán1,Bálint Hajnalka O.1,Környei László2,Ruzsa Diána3,Fődi Eszter3,Simor Tamás3,Kardos Attila1

Affiliation:

1. Adult Cardiology Department Gottsegen National Cardiovascular Center Budapest Hungary

2. Pediatric Cardiology Department Gottsegen National Cardiovascular Center Budapest Hungary

3. University of Pécs Medical School Heart Institute Pécs Hungary

Abstract

AbstractBackgroundCatheter ablation is a rarely used procedure to treat arrhythmias during pregnancy.HypothesisIn the case of maternal arrhythmia during pregnancy, zero‐fluoroscopic catheter ablation is preferable to medical treatment.MethodsBetween April 2014 and September 2021, we examined the demographic data, procedural parameters, and fetal and maternal outcomes in pregnant women undergoing ablation at the Gottsegen National Cardiovascular Center and University of Pécs Medical School, Heart Institute.ResultsFourteen procedures (14 electrophysiological studies [EPS], 13 ablations) performed on 13 pregnant women (age 30.3 ± 5.2 years, primipara n = 6) were studied. During EPS, 12 patients had inducible arrhythmias. Atrial tachycardia was confirmed in three, atrioventricular re‐entry tachycardia via manifest accessory pathway (AP) in three, and via concealed AP in one case. Atrioventricular nodal re‐entry tachycardia was confirmed in three and sustained monomorphic ventricular tachycardia in two cases. Eleven radiofrequency ablation (84.6%) and two cryoablation (15.4%) were performed. The electroanatomical mapping system was used in all cases. Transseptal puncture was performed in two cases (15.4%) due to left lateral APs. The mean procedure time was 76.0±33.0 minutes. All procedures were performed without fluoroscopy. No complications occurred. During the follow‐up, arrhythmia‐free survival was achieved in all cases, but in two patients, we used antiarrhythmic drugs (AADs) to achieve it. APGAR score was within the normal range in all cases [median (interquartile range), 9.0/10.0 (9.0–10.0/9.3–10.0)].ConclusionsZero‐fluoroscopic catheter ablation was an effective and safe treatment option for our 13 pregnant patients. Catheter ablation may have less side effects on fetal development than the use of AADs during pregnancy.

Publisher

Wiley

Subject

Cardiology and Cardiovascular Medicine,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370