Adaptive complementary neighboring sub‐aperture beamforming for thermoacoustic imaging

Author:

Yang Zeqi1,Wang Fuyong1,Peng Wanting2,Song Ling3,Luo Yan3,Zhao Zhiqin1,Huang Lin1

Affiliation:

1. School of Electronic Science and Engineering University of Electronic Science and Technology of China Chengdu Sichuan China

2. School of Information Engineering Southwest University of Science and Technology Mianyang Sichuan China

3. Department of Ultrasound West China Hospital, Sichuan University Chengdu Sichuan China

Abstract

AbstractBackgroundWhen applied to thermoacoustic imaging (TAI), the delay‐and‐sum (DAS) algorithm produces strong sidelobes due to its disadvantages of uniform aperture weighting. As a result, the quality of TAI images recovered by DAS is often severely degraded by strong non‐coherent clutter, which restricts the development and application of TAI.PurposeTo address this issue, we propose an adaptive complementary neighboring sub‐aperture (NSA) beamforming algorithm for TAI.MethodsIn NSA, we introduce a coordinate system transformation when calculating the normalized cross‐correlation (NCC) matrix. This approach enables the computation of the NCC coefficient within the specified kernel without complex coordinate calculations. We first conducted the numerical simulation experiment to validate NSA using a tree branch phantom. In addition, we also conducted phantom (five sauce tubes), ex vivo (ablation needle in ex vivo porcine liver), and in vivo (human arm) TAI experiments using our TAI system with a center frequency of 3 GHz.ResultsIn the numerical simulation experiment, the structural similarity index (SSIM) value for NSA is increased from 0.37828 for DAS to 0.75492. In the point target phantom TAI experiment, the generalized contrast‐to‐noise ratio (gCNR) value for NSA is increased from 0.936 for DAS to 0.962. The experimental results show that NSA can recover clearer thermoacoustic images compared to DAS. In the ex vivo TAI experiment, the full width at half maxima (FWHM) of an ablation needle (diameter = 1.5 mm) for coherence factor (CF) weighted DAS and NSA are 0.9 and 1.3 mm, respectively. Furthermore, in the in vivo TAI experiment, CF reduces the signals within the arm compared to NSA. Therefore, compared with CF, NSA can maintain the integrity of target information in TAI while effectively suppressing non‐coherent background clutter.ConclusionsNSA can effectively reduce non‐coherent background noise while ensuring the completeness of the target information. So, NSA offers the potential to provide high‐quality thermoacoustic images and further advance their clinical application.

Funder

National Natural Science Foundation of China

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3