X‐ray reconstruction of moving morphology (XROMM): precision, accuracy and applications in comparative biomechanics research

Author:

Brainerd Elizabeth L.,Baier David B.,Gatesy Stephen M.,Hedrick Tyson L.,Metzger Keith A.,Gilbert Susannah L.,Crisco Joseph J.

Abstract

AbstractX‐Ray Reconstruction of Moving Morphology (XROMM) comprises a set of 3D X‐ray motion analysis techniques that merge motion data from in vivo X‐ray videos with skeletal morphology data from bone scans into precise and accurate animations of 3D bones moving in 3D space. XROMM methods include: (1) manual alignment (registration) of bone models to video sequences, i.e., Scientific Rotoscoping; (2) computer vision‐based autoregistration of bone models to biplanar X‐ray videos; and (3) marker‐based registration of bone models to biplanar X‐ray videos. Here, we describe a novel set of X‐ray hardware, software, and workflows for marker‐based XROMM. Refurbished C‐arm fluoroscopes retrofitted with high‐speed video cameras offer a relatively inexpensive X‐ray hardware solution for comparative biomechanics research. Precision for our biplanar C‐arm hardware and analysis software, measured as the standard deviation of pairwise distances between 1 mm tantalum markers embedded in rigid objects, was found to be ±0.046 mm under optimal conditions and ±0.084 mm under actual in vivo recording conditions. Mean error in measurement of a known distance between two beads was within the 0.01 mm fabrication tolerance of the test object, and mean absolute error was 0.037 mm. Animating 3D bone models from sets of marker positions (XROMM animation) makes it possible to study skeletal kinematics in the context of detailed bone morphology. The biplanar fluoroscopy hardware and computational methods described here should make XROMM an accessible and useful addition to the available technologies for studying the form, function, and evolution of vertebrate animals. J. Exp. Zool. 313A:262–279, 2010. © 2010 Wiley‐Liss, Inc.

Publisher

Wiley

Reference48 articles.

1. A method to estimate in vivo dynamic articular surface interaction

2. Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy

3. American College of Cardiology/Society for Cardiac Angiography and Interventions Clinical Expert Consensus Document on Cardiac Catheterization Laboratory Standards41When citing this document, the American College of Cardiology and the Society for Cardiac Angiography and Interventions would appreciate the following citation format: Bashore TM, Bates ER, Berger PB, Clark DA, Cusma JT, Dehmer GJ, Kern MJ, Laskey WK, O’Laughlin MP, Oesterle S, Popma JJ. Cardiac catheterization laboratory standards: a report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents (ACC/SCA&I Committee to Develop an Expert Consensus Document on Cardiac Catheterization Laboratory Standards). J Am Coll Cardiol 2001;37:2170–214.44Address for reprints: This document is available on the Web sites of the American College of Cardiology (http://www.acc.org) and the Society for Cardiac Angiography and Interventions (http://www.scai.org). Reprints of this document may be purchased for $5 each by calling 1-800-253-4636, ext 694, or by writing to the American College of Cardiology, Educational Services, 9111 Old Georgetown Road, Bethesda, MD 20814-1699.

4. Validation of a New Model-Based Tracking Technique for Measuring Three-Dimensional, In Vivo Glenohumeral Joint Kinematics

5. Measuring dynamic in-vivo glenohumeral joint kinematics: Technique and preliminary results