Double-Balloon Enteroscopy following Capsule Endoscopy in the Management of Obscure Gastrointestinal Bleeding: Outcome of a Combined Approach

Author:

Kamalaporn Patarapong1,Cho Sarah1,Basset Nancy1,Cirocco Maria1,May Gary1,Kortan Paul1,Kandel Gabor1,Marcon Norman1

Affiliation:

1. Centre for Therapeutic Endoscopy and Endoscopic Oncology, St Michael’s Hospital, University of Toronto, Toronto, Ontario, Canada

Abstract

BACKGROUND: There is no consensus on the relative accuracy of capsule endoscopy (CE) versus double-balloon enteroscopy (DBE) to investigate obscure gastrointestinal bleeding (GIB). CE is less invasive, but DBE more directly examines the small bowel, and allows tissue sampling plus therapeutic intervention.OBJECTIVES: To evaluate the yield and outcome of DBE following CE in patients with obscure GIB.METHODS: After DBE became readily available at the Centre for Therapeutic Endoscopy and Endoscopic Oncology (St Michael’s Hospital, Toronto, Ontario), all patients with obscure GIB seen from December 2002 to June 2007 were evaluated identically, first with CE, then with DBE (some with further interventions). Findings, adverse outcomes and interventions are reported.RESULTS: Fifty-one patients (25 women) with a mean (range) age of 64.1 years (34 to 83 years) are reported. Eight patients underwent DBE twice, for a total of 59 DBEs. Fourteen patients had overt GIB and the median (range) number of red blood cell unit transfusions was 10 (0 to 100). The positive findings for each type of lesion were compared in these 51 patients: angiodysplasia (CE 64.7% and DBE 61%, P=0.3), ulcers (CE 19.6% and DBE 18.6%, P=0.5), bleeding lesions (CE 43.1% and DBE 15.3%, P=0.0004) and mass (CE 10.2% and DBE 8.5%, P=0.5). DBE provided the advantage of therapeutic intervention: argon plasma coagulation (33 of 59 DBEs), clipping (two of 59), both argon plasma coagulation and clipping (three of 59), polypectomy (two of 59), tattooing (52 of 59) and biopsies (11 of 59). DBE detected lesions not seen by CE in 21 patients; lesions were treated in 18 patients. However, CE detected 31 lesions not seen by DBE. No major complications occurred with either examination.CONCLUSION: Overall detection rates for both techniques are similar. Each technique detected lesions not seen by the other. These data suggest that CE and DBE are complementary and that both evaluate obscure GIB more fully than either modality alone.

Publisher

Hindawi Limited

Subject

Gastroenterology,General Medicine

Cited by 45 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3