Chest Computed Tomography Images in Neonatal Bronchial Pneumonia under the Adaptive Statistical Iterative Reconstruction Algorithm

Author:

Sun Ying1ORCID,Wu Liao2ORCID,Tian Zhaofang1ORCID,Bao Tianping1ORCID

Affiliation:

1. Department of Neonatology, The Affiliated Huai’an No. 1 People’s Hospital of Nanjing Medical University, Huai’an 223300, Jiangsu, China

2. Department of Neurology, The Affiliated Huai’an No. 1 People’s Hospital of Nanjing Medical University, Huai’an 223300, Jiangsu, China

Abstract

This study was to explore the application value of chest computed tomography (CT) images processed by artificial intelligence (AI) algorithms in the diagnosis of neonatal bronchial pneumonia (NBP). The AI adaptive statistical iterative reconstruction (ASiR) algorithm was adopted to reconstruct the chest CT image to compare and analyze the effect of the reconstruction of CT image under the ASiR algorithm under different preweight and postweight values based on the objective measurement and subjective evaluation. 85 neonates with pneumonia treated in hospital from September 1, 2015, to July 1, 2020, were selected as the research objects to analyze their CT imaging characteristics. Subsequently, the peripheral blood of healthy neonates during the same period was collected, and the levels of C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR) were detected. The efficiency of CT examination, CRP, ESR, and combined examination in the diagnosis of NBP was analyzed. The results showed that the subjective quality score, lung window subjective score, and mediastinal window subjective score were the highest after CT image reconstruction when the preweight value of the ASiR algorithm was 50%. After treatment, 79 NBP cases (92.9%) showed ground-glass features in CT images. Compared with the healthy neonates, the levels of CRP and ESR in the peripheral blood of neonates with bronchial pneumonia were much lower ( P < 0.05 ). The accuracy rates of CT examination, CRP examination, ESR examination, CRP + ESR examination, and CRP + ESR + CT examination for the diagnosis of NBP were 80.7%, 75.3%, 75.1%, 80.3%, and 98.6%, respectively. CT technology based on AI algorithm showed high clinical application value in the feature analysis of NBP.

Publisher

Hindawi Limited

Subject

Health Informatics,Biomedical Engineering,Surgery,Biotechnology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3