The Pattern of Use, Effectiveness, and Safety of Gadoteric Acid (Clariscan) in Patients Undergoing Contrast-Enhanced Magnetic Resonance Imaging: A Prospective, Multicenter, Observational Study

Author:

Moon Won-Jin1ORCID,Cho Young Ah2ORCID,Hahn Seok3ORCID,Son Hye Min4ORCID,Woo Sung Koo5ORCID,Lee Young Han6ORCID

Affiliation:

1. Department of Radiology, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul, Republic of Korea

2. Department of Radiology, Asan Medical Center, Seoul, Republic of Korea

3. Department of Radiology, Inje University Haeundae Paik Hospital, Busan, Republic of Korea

4. Department of Radiology, Yeungnam University Medical Center, Daegu, Republic of Korea

5. Department of Radiology, Dong-Eui Medical Center, Busan, Republic of Korea

6. Department of Radiology, Yonsei University College of Medicine, Seoul, Republic of Korea

Abstract

Objective. Contrast-enhanced MR (CE-MR) imaging is often required to improve lesion detection and characterization and to increase diagnostic confidence. This study aimed to evaluate the safety and effectiveness, as well as the use pattern, of the macrocyclic gadolinium-based contrast agent Clariscan in real-world clinical practice in Korea. Materials and Methods. This was a prospective, multicenter, observational study of patients undergoing CE-MR as part of routine clinical care at 6 university hospitals in Korea. Effectiveness was evaluated by determining diagnostic confidence and image quality; safety evaluation included the adverse event (AE) expression rate. Subgroup analyses were conducted by body regions of diagnosis (musculoskeletal, nervous system, others) and in pediatric patients (aged ≤7 years). Results. From October 2019 to September 2020, 1,376 subjects were included in the study. The mean volume of Clariscan used was 0.26 mL/kg (0.13 mmol/kg). In the overall study population and in each subgroup, diagnostic confidence increased after contrast enhancement with Clariscan. Overall, image quality was excellent in 72.5% of subjects and good-to-adequate in 27.2%. Clariscan was well tolerated (14 AEs occurred in 10 subjects); all AEs were of mild severity. Subgroup analyses showed that the mean dose of Clariscan used was ≥0.1 mmol/kg for nervous system-related diagnoses (e.g., brain) and ≤0.1 mmol/kg for musculoskeletal and pediatric-related diagnoses. All musculoskeletal and pediatric examinations were provided with a smaller package of 5 mL Clariscan. By body region of MR examination, the most common region was the nervous system in 69.0%, musculoskeletal system in 13.6%, and reproductive system in 4.9%. Conclusions. This study confirmed the use pattern of Clariscan and its excellent effectiveness and safety in the real-world clinical environment in Korea. The small-dose package indicated the possibility of increasing the convenience and efficiency of drug use.

Funder

GE Healthcare Korea

Publisher

Hindawi Limited

Subject

Radiology Nuclear Medicine and imaging

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3