Evaluation of Myelin Radiotracers in the Lysolecithin Rat Model of Focal Demyelination: Beware of Pitfalls!

Author:

Zhang Min123ORCID,Hugon Gaëlle12,Bouillot Caroline4,Bolbos Radu4,Langlois Jean-Baptiste4,Billard Thierry456ORCID,Bonnefoi Frédéric4,Li Biao3,Zimmer Luc147,Chauveau Fabien12ORCID

Affiliation:

1. University of Lyon, Lyon Neuroscience Research Center (CRNL), Lyon, France

2. CNRS UMR5292, INSERM U1028, University of Lyon 1, F-69003 Lyon, France

3. Shanghai Jiao Tong University, School of Medicine, Department of Nuclear Medicine, Rui Jin Hospital, Shanghai, China

4. CERMEP-Imagerie Du Vivant, F-69677 Bron, France

5. University of Lyon, Institute of Chemistry and Biochemistry (ICBMS), Lyon, France

6. CNRS UMR5246, University of Lyon 1, F-69622 Lyon, France

7. Hospices Civils de Lyon, F-69677 Bron, France

Abstract

The observation that amyloid radiotracers developed for Alzheimer’s disease bind to cerebral white matter paved the road to nuclear imaging of myelin in multiple sclerosis. The lysolecithin (lysophosphatidylcholine (LPC)) rat model of demyelination proved useful in evaluating and comparing candidate radiotracers to target myelin. Focal demyelination following stereotaxic LPC injection is larger than lesions observed in experimental autoimmune encephalitis models and is followed by spontaneous progressive remyelination. Moreover, the contralateral hemisphere may serve as an internal control in a given animal. However, demyelination can be accompanied by concurrent focal necrosis and/or adjacent ventricle dilation. The influence of these side effects on imaging findings has never been carefully assessed. The present study describes an optimization of the LPC model and highlights the use of MRI for controlling the variability and pitfalls of the model. The prototypical amyloid radiotracer [11C]PIB was used to show that in vivo PET does not provide sufficient sensitivity to reliably track myelin changes and may be sensitive to LPC side effects instead of demyelination as such. Ex vivo autoradiography with a fluorine radiotracer should be preferred, to adequately evaluate and compare radiotracers for the assessment of myelin content.

Funder

National Natural Science Foundation of China

Publisher

Hindawi Limited

Subject

Radiology, Nuclear Medicine and imaging

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3