A Method to Evaluate and Eliminate Fungal Contamination in Household Air Conditioners

Author:

Shiraishi Yoshiki1ORCID,Harada Kazuhiro2,Maeda Chikao2,Ogino Fumitoshi2,Suzuki Yu3,Okada Naoki1,Tomomatsu Katsuyoshi1,Sekine Yoshika4,Yanagi U.5,Imanishi Tadashi3,Oguma Tsuyoshi1,Asano Koichiro1ORCID

Affiliation:

1. Division of Pulmonary Medicine, Department of Medicine, Tokai University School of Medicine, Kanagawa, Japan

2. Research and Development, Duskin Co., Ltd., Suita, Osaka, Japan

3. Department of Molecular Life Science, Tokai University School of Medicine, Kanagawa, Japan

4. Department of Chemistry, School of Science, Tokai University, Kanagawa, Japan

5. Department of Architecture, School of Architecture, Kogakuin University, Tokyo, Japan

Abstract

Background. Allergic fungal airway diseases, such as asthma and allergic bronchopulmonary mycosis (ABPM), are often difficult to manage with medical treatment alone; therefore, environmental fungal exposure should be accurately evaluated and minimized. In the present study, we established a method to evaluate and eliminate fungal contamination in household air conditioners (ACs). Methods. In the fall of 2020, an environmental survey of living rooms was conducted in 17 Japanese residences of patients with ABPM or related diseases. Household ductless minisplit AC units were disassembled to collect swab samples from the internal parts (filter, heat exchanger, blower fan, and air vent), followed by high-pressure washing. Fungal abundance and composition in swab samples and cleaning effluents of ACs as well as house dust and air samples were determined using quantitative PCR and next-generation sequencing of the internal transcribed spacer 1 region, respectively. A weighted UniFrac distance was calculated to analyze the similarity of the mycobiome among the samples. Results. All interior parts of ACs contained high levels of fungal DNA, with the blower fans being the most contaminated parts. Cladosporium and Toxicocladosporium, followed by Aureobasidium, Aspergillus, and Rhodotorula, were the most common fungi detected in the AC unit. High-pressure washing decreased fungal abundance by over 99% in all AC parts. Fungal abundance and composition in blower fans were strongly correlated with those in cleaning effluents. Conclusion. Interior parts downstream of heat exchangers in household ACs are the major sites of fungal contamination, possibly polluting the indoor air in the residences. High-pressure washing is highly effective for decontamination.

Funder

Tokai University

Publisher

Hindawi Limited

Subject

Public Health, Environmental and Occupational Health,Building and Construction,Environmental Engineering