Analysis of Carbon Fiber Reinforced PEEK Hinge Mechanism Articulation Components in a Rotating Hinge Knee Design: A Comparison of In Vitro and Retrieval Findings

Author:

Schierjott Ronja A.12ORCID,Giurea Alexander3,Neuhaus Hans-Joachim4ORCID,Schwiesau Jens25ORCID,Pfaff Andreas M.2,Utzschneider Sandra5ORCID,Tozzi Gianluca1,Grupp Thomas M.25ORCID

Affiliation:

1. School of Engineering, University of Portsmouth, Portsmouth PO1 3DJ, UK

2. Aesculap AG, Research & Development, Am Aesculap-Platz, 78532 Tuttlingen, Germany

3. Department of Orthopaedics, Vienna General Hospital, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria

4. Department of Traumatology and Orthopaedics, St. Vincenz Hospital, Am Stein 24, 58706 Menden, Germany

5. Department of Orthopaedic Surgery, Physical Medicine & Rehabilitation, Ludwig Maximilians University Munich, Campus Grosshadern, Marchioninistrasse 15, 81377 Munich, Germany

Abstract

Carbon fiber reinforced poly-ether-ether-ketone (CFR-PEEK) represents a promising alternative material for bushings in total knee replacements, after early clinical failures of polyethylene in this application. The objective of the present study was to evaluate the damage modes and the extent of damage observed on CFR-PEEK hinge mechanism articulation components after in vivo service in a rotating hinge knee (RHK) system and to compare the results with corresponding components subjected to in vitro wear tests. Key question was if there were any similarities or differences between in vivo and in vitro damage characteristics. Twelve retrieved RHK systems after an average of 34.9 months in vivo underwent wear damage analysis with focus on the four integrated CFR-PEEK components and distinction between different damage modes and classification with a scoring system. The analysis included visual examination, scanning electron microscopy, and energy dispersive X-ray spectroscopy, as well as surface roughness and profile measurements. The main wear damage modes were comparable between retrieved and in vitro specimens (n=3), whereby the size of affected area on the retrieved components showed a higher variation. Overall, the retrieved specimens seemed to be slightly heavier damaged which was probably attributable to the more complex loading and kinematic conditions in vivo.

Publisher

Hindawi Limited

Subject

General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Comparative Study of Zirconium Nitride Multilayer Coatings: Crystallinity, In Vitro Oxidation Behaviour and Tribological Properties Deposited via Sputtering and Arc Deposition;Journal of Functional Biomaterials;2024-08-13

2. Tribologie in der Endoprothetik;Die Orthopädie;2024-06-04

3. Modern Coatings in Knee Arthroplasty;Arthroplasty - Advanced Techniques and Future Perspectives;2023-03-08

4. Nanoparticles in Joint Arthroplasties;Nano LIFE;2023-02-25

5. Stress Distribution in Femoral Stems for Revision Total Knee Arthroplasty with Three Different Materials: A Comparative Finite Element Study;2022 29th National and 7th International Iranian Conference on Biomedical Engineering (ICBME);2022-12-21