The Effect of Position on Radiographic Angle Measurements of the Lower Extremities

Author:

Chung Jeehyeok12ORCID,Lee Joonhee1,Han Hyuk-Soo12ORCID,Lee Myung Chul12ORCID,Ro Du Hyun123ORCID

Affiliation:

1. Department of Orthopedic Surgery, Seoul National University Hospital, Seoul, Republic of Korea

2. Seoul National University College of Medicine, Seoul, Republic of Korea

3. CONNECTEVE Co., Ltd, Republic of Korea

Abstract

Purpose. Accurately measuring an angle on a lower extremity X-ray is essential for the diagnosis and treatment of knee osteoarthritis (KOA). However, the angle is often affected by position, especially with flexion contracture and rotation. To date, there have been no quantitative analyses examining the relationship between lower extremity angle and patient position and no studies targeting patients with deformities. The aim of this study is to quantify the effect of position on angle measurements in lower extremity X-rays and to compare the effect in patients with different deformities. Methods. Computed tomography (CT) data of 131 patients with knee pain were retrospectively analyzed. The subjects were categorized into the following groups: neutral (hip-knee-ankle angle (HKAA) between 175 and 185°), varus (HKAA less than 175°), valgus (HKAA more than 185°), and flexion (flexion contracture more than 10°). CT images were digitally reconstructed to anterior-posterior X-ray images using an average intensity projection algorithm. The process was then repeated while rotating the reconstruction plane from internal 9° to external 9°. In this manner, X-ray images were reconstructed in different rotational states. The following angles were measured from reconstructed X-ray images: HKAA, lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), and femoral valgus angle (FVA). The measurements were then compared according to the degree of rotation. Results. FVA significantly differed according to rotation in all groups ( P < 0.001 ), with a difference of 1.3° (±0.4°). HKAA significantly changed only in the flexion contracture group ( P < 0.001 ), which showed a difference of 1.0° (±0.7°). However, HKAA in the other groups, LDFA, and MPTA did not significantly differ depending on rotation. Conclusions. Radiographic measurement of FVA is subject to change according to rotation. HKAA significantly changed only in the flexion contracture group, so more care should be taken while obtaining X-rays of patients with flexion contracture.

Publisher

Hindawi Limited

Subject

General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3