Optical Surface Management System and BladderScan for Patient Setup During Radiotherapy of Postoperative Prostate Cancer

Author:

Chen Hao,Liu Yandong,Qin SongbinORCID,Gan GuanghuiORCID

Abstract

Background: The precision of postoperative prostate cancer radiotherapy is significantly influenced by setup errors and alterations in bladder morphology. Utilizing daily cone beam computed tomography (CBCT) imaging allows for the correction of setup errors. However, this naturally leads to the question of the issue of peripheral dose and workload. Thus, a zero‐dose, noninvasive technique to reproduce the bladder volume and improve patient setup accuracy was needed.Purpose: The aim of this study is to investigate if the setup method by combining Optical Surface Management System (OSMS) and BladderScan can improve the accuracy of setup and accurately reproduce the bladder volume during radiotherapy of postoperative prostate cancer and to guide CTV‐PTV margins for clinic.Method: The experimental group consisted of 15 postoperative prostate cancer patients who utilized a setup method that combined OSMS and BladderScan. This group recorded 103 setup errors, verified by CBCT. The control group comprised 25 patients, among whom 114 setup errors were recorded using the conventional setup method involving skin markers; additionally, patients in this group also exhibited spontaneous urinary suppression. The errors including lateral (Lat), longitudinal (Lng), vertical directions (Vrt), Pitch, Yaw, and Roll were analyzed between the two methods. The Dice similarity coefficient (DSC) and volume differences of the bladder between CBCT and planning CT were compared as the bladder concordance indicators.Results: The errors in the experimental group at Vrt, Lat, and Lng were 0.17 ± 0.12, 0.22 ± 0.17, and 0.18 ± 0.12 cm, and the control group were 0.25 ± 0.15, 0.31 ± 0.21, 0.34 ± 0.22 cm. The rotation errors of Pitch, Roll, and Yaw in the experimental group were 0.18 ± 0.12°, 0.11 ± 0.1°, and 0.18 ± 0.13°, and in the control group, they were 0.96 ± 0.89°, 1.01 ± 0.86°, and 1.02 ± 0.84°. The DSC and volume differences were 92.52 ± 1.65% and 39.99 ± 28.75 cm3 in the patients with BladderScan, and in the control group, they were 62.98 ± 22.33%, 273.89 ± 190.62 cm3. The P < 0.01 of the above performance indicators indicates that the difference is statistically significant.Conclusion: The accuracy of the setup method by combining OSMS and BladderScan was validated by CBCT in our study. The method in our study can improve the setup accuracy during radiotherapy of postoperative prostate cancer compared to the conventional setup method.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3