Personalization of CM Injection Protocols in Coronary Computed Tomographic Angiography (People CT Trial)

Author:

Eijsvoogel N. G.12ORCID,Hendriks B. M. F.12,Nelemans P.3,Mihl C.12,Willigers J.1,Martens B.12,Wildberger J. E.12,Das M.124

Affiliation:

1. Department of Radiology, Maastricht University Medical Center+, P. Debyelaan 25, PO Box 5800, 6202 AZ Maastricht, Netherlands

2. CARIM School for Cardiovascular Diseases, Maastricht University Medical Center+, Maastricht, Netherlands

3. Department of Epidemiology, Faculty of Health, Medicine and Life Sciences, Maastricht University, Maastricht, Netherlands

4. Department of Diagnostic and Interventional Radiology, Helios Kliniken Duisburg, Duisburg, Germany

Abstract

Aim. To evaluate the performance of three contrast media (CM) injection protocols for cardiac computed tomography angiography (CCTA) based on body weight (BW), lean BW (LBW), and cardiac output (CO). Materials and methods. A total of 327 consecutive patients referred for CCTA were randomized into one of the three CM injection protocols, where CM injection was based on either BW (112 patients), LBW (108 patients), or CO (107 patients). LBW and CO were calculated via formulas. All scans were ECG-gated and performed on a third-generation dual-source CT with 70–120 kV (automated tube voltage selection) and 100 kVqual.ref/330 mAsqual.ref. CM injection protocols were also adapted to scan time and tube voltage. The primary outcome was the proportion of patients with optimal intravascular attenuation (325–500 HU). Secondary outcomes were mean and standard deviation of intravascular attenuation values (HU), contrast-to-noise ratio (CNR), and subjective image quality with a 4-point Likert scale (1 = poor/2 = sufficient/3 = good/4 = excellent). The t-test for independent samples was used for pairwise comparisons between groups, and a chi-square test (χ2) was used to compare categorical variables between groups. All p values were 2-sided, and a p<0.05 was considered statistically significant. Results. Mean overall HU and CNR were 423 ± 60HU/14 ± 3 (BW), 404 ± 62HU/14 ± 3 (LBW), and 413 ± 63HU/14 ± 3 (CO) with a significant difference between groups BW and LBW (p=0.024). The proportion of patients with optimal intravascular attenuation (325–500 HU) was 83.9%, 84.3%, and 86.9% for groups BW, LBW, and CO, respectively, and between-group differences were small and nonsignificant. Mean CNR was diagnostic (≥10) in all groups. The proportion of scans with good-excellent image quality was 94.6%, 86.1%, and 90.7% in the BW, LBW, and CO groups, respectively. The difference between proportions was significant between the BW and LBW groups. Conclusion. Personalization of CM injection protocols based on BW, LBW, and CO, and scan time and tube voltage in CCTA resulted in low variation between patients in terms of intravascular attenuation and a high proportion of scans with an optimal intravascular attenuation. The results suggest that personalized CM injection protocols based on LBW or CO have no additional benefit when compared with CM injection protocols based on BW.

Publisher

Hindawi Limited

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370