CAMPO Precision128 Max ENERGY Spectrum CT Combined with Multiple Parameters to Evaluate the Benign and Malignant Pleural Effusion

Author:

Zhang Tianyu1,Wu Cuicui2,Li Zhongtao2,Ding Yan3,Wen Lijuan4,Wang Li4ORCID

Affiliation:

1. CT Section of The Second Hospital Affiliated Qiqihar Medical University, Qiqihar 161000, Heilongjiang, China

2. Qiqihar Medical University, Qiqihar 161000, Heilongjiang, China

3. Ultrasound Department, The Third Hospital Affiliated Qiqihar Medical University, Qiqihar 161000, Heilongjiang, China

4. Radiology Center, The Third Hospital Affiliated Qiqihar Medical University, Qiqihar 161000, Heilongjiang, China

Abstract

The emergence of energy spectrum CT provides greater diagnostic value for clinical practice. Its advantage is that it can provide more functional imaging parameters and accurate image information for clinical practice, which represents a mainstream direction of CT technology development at present. This paper mainly studies the clinical trial of CAMPO Precision128 Max ENERGY spectrum CT combined with multiple parameters to evaluate the benign and malignant pleural effusion. This paper analyzes the principle and key performance parameters of energy spectrum CT imaging, the etiology of pleural effusion, and its conventional diagnostic methods and uses energy spectrum CT to detect the benign and malignant pleural effusion. In this paper, two groups of patients with different types of pleural effusions were scanned by line spectrum chest CT scans, and energy spectrum analysis software was used to measure and calculate the CT values of conventional mixed energy values of ROI of patients with pleural effusions. For the CT value and energy curve slope measurement value of different single energy keV, independent sample t-test was used to analyze and compare the two sets of data, and finally it has been found out that the two sets of data were similar. According to the experimental results, the curves of energy spectrum of the two groups of data are similar in the descending curve of bow-back. The slope of energy spectrum curve in the leakage group was lower than that in the exudate group, showing statistical significance ( P < 0.05 ). The slope of energy spectrum curve K in the malignant pleural effusion group was significantly higher than that in the benign pleural effusion group, and the difference was statistically significant ( P < 0.05 ). The trend of energy spectrum curves of the two is roughly the same, while at the high energy level, part of the energy spectrum curves of the two are overlapped. The above conclusion indicates that energy spectrum CT plays a certain role in the differential diagnosis of pleural effusion. At the same time, energy spectrum CT also provides a noninvasive and rapid examination method for clinical differentiation of pleural effusion, which has certain clinical application value and prospect.

Publisher

Hindawi Limited

Subject

Health Informatics,Biomedical Engineering,Surgery,Biotechnology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3