Abstract

Background. Volume overload is a fatal complication for people undergoing hemodialysis. Therefore, regulating a patient’s “dry weight” based on their fluid status is imperative. Clinical experiences are too subjective to accurately judge a patient’s fluid status, but techniques have emerged for improved fluid control in the two decades. Specifically, lung ultrasonography (LUS) uses a unique aspect of ultrasound images, the B-lines, to evaluate extravascular lung water, which has increasingly attracted attention. However, the role of B-line quantification in predicting short-mid-term death and/or cardiovascular complications is unclear. Methods. Patients undergoing MHD at the hemodialysis center of Zhejiang Provincial People’s Hospital from October 1, 2020, to February 28, 2021, were examined using LUS and a bioelectrical impedance analysis before and after dialysis, and related clinical data were collected. All patients were followed up for one year after the examination, and deaths and first cardiovascular events (e.g., stroke, myocardial infarction, and heart failure) during this period were recorded. Results. 98 patients were enrolled and divided into three groups in relation to their mild (<16 B-lines), moderate (16–30 B-lines), or severe (>30 B-lines) hypervolemia, defined by the number of B-lines. The long-term survival rate was significantly lower in the severe group than in the mild and moderate groups. LUS and bioelectrical impedance-related parameters (e.g., extracellular water-to-water ratio) were closely related to cardiac ultrasound parameters (left ventricular ejection fraction) (P<0.001). The optimal B-line cutoff value on LUS for predicting fluid overload (defined clinically) in patients on hemodialysis was 11.5 lines (AUC = 0.840, 95% confidence interval 0.735–0.945, P<0.001), and the diagnostic sensitivity and specificity were both 76.5%. During the one-year follow-up period, ten deaths and six cardiovascular events occurred. The survival rate was significantly lower in the severe group than in the mild group (log-rank test χ2 = 10.050, P=0.002) but did not differ between the severe and moderate groups (χ2 = 2.629, P=0.105). Conclusion. LUS is a cheap, noninvasive, simple, and repeatable volume-monitoring method that can assist with individualized fluid volume management in patients undergoing MHD. LUS results may also help to predict the short-mid-term survival rate of patients to a certain extent.

Funder

Medical Science and Technology Project of Zhejiang Province

Publisher

Hindawi Limited

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3