Magnetic Resonance Imaging Feature Analysis and Evaluation of Tubal Patency under Convolutional Neural Network in the Diagnosis of Infertility

Author:

Liu Na1ORCID,Ren Qingling1ORCID

Affiliation:

1. First Clinical Medical College, Nanjing University of Chinese Medicine, Nanjing 210023, Jiangsu, China

Abstract

To explore the diagnostic value of MRI image features based on convolutional neural network for tubal unobstructed infertility, 30 infertile female patients were first selected as the research objects, who admitted to the hospital from May 2018 to January 2020. They all underwent routine MRI examinations and CNN-based MR-hysteron-salpingography (HSG) examinations, in order to discuss the diagnostic accuracy of the two examinations. In the research, it was necessary to observe the patients’ imaging results, calculate the diagnosis rate of the two examination results, and analyze the application effect of the CNN algorithm, thereby selecting the best reconstruction method. In this study, the analysis was conducted on the basis of no statistical difference in the baseline data of the included patients. The results of undersampling reconstruction at 2-fold, 4-fold, and 6-fold showed that CNN for data consistency layer (CNN_DC) had a better effect, and its peak signal-to-noise ratio (PSNR) was lower sharply than that of the other two reconstruction methods, while the normalized mean square error (NMSE) and structural similarity index measure (SSIM) were higher markedly than the values of the other two reconstruction methods. The diagnostic rate of routine MRI examination of the fallopian tube and other parts of the uterus was lower than or equal to that of MR-HSG examination by CNN. Routine MRI examinations of fallopian tube imaging artifacts were large, and the definition was reduced, which increased the difficulty of identification. However, MR-HSG examination by CNN indicated that the imaging artifacts were low, the clarity was high, and the influence of noise was small, which was conducive to clinical diagnosis and identification. For endometriosis, the accuracy of MR-HSG was 33.33% and the accuracy of MRI was 46.67%. CNN MR-HSG inspection method was significantly better than the conventional MRI inspection method P < 0.05 . Therefore, the results of this study revealed that MR-HSG examination by CNN had a clear imaging effect and obvious inhibition effect on background signals and rapid image generation without the need for reconstruction with the same spatial resolution, which improved the imaging quality and could provide a reference value for clinical diagnosis and subsequent related studies.

Publisher

Hindawi Limited

Subject

Radiology Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3