Application of Transesophageal Echocardiography in Amplatzer Atrial Septal Defect Occluder for Percutaneous Closure of Large Patent Foramen Ovale

Author:

Du Yajuan1,Xie Hang1ORCID,Shao Hui1,Cheng Gesheng1,He Lu1,Wang Xingye1,He Xumei1,Lan Beidi1,Zhang Yushun1,Tian Gang2ORCID

Affiliation:

1. Department of Structural Heart Disease, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an, Shaanxi Province, China

2. Department of Cardiology, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an, Shaanxi Province, China

Abstract

Objective. The Amplatzer patent foramen ovale (PFO) occluder is the most commonly used device for percutaneous closure of a large PFO. However, its use may predispose the patient to postoperative residual shunting. To reduce the incidence of residual shunting, we investigated the safety and effectiveness of the Amplatzer atrial septal defect (ASD) occluder for percutaneous closure of a large PFO measured by transesophageal echocardiography (TEE) and evaluated the value of TEE in this procedure. Methods. Overall, 118 patients who were diagnosed with a large PFO (all with a 2  mm left atrial side height after the Valsalva maneuver (VM) excluding those with a small ASD) using contrast transthoracic echocardiography (c-TTE) and TEE underwent closure under TEE guidance at The First Affiliated Hospital of Xi’an Jiaotong University. An ASD device was used in 48 patients (group I) and a PFO device in 70 (group II). After the procedure, we verified the safety and efficacy of different devices using c-TTE, TTE, and TEE. Results. In both groups, the preoperative TEE results showed a significantly increased left height of the PFO after VM compared with that at rest (all P < 0.01 ). Compared with the left height of the PFO measured using TEE after VM, the PFO-stretch diameter (SD) measured by TEE after the delivery sheath passed the PFO was higher (all P < 0.01 ). We selected the ASD occluder size according to this PFO-SD. In group II, most patients underwent the implantation of the larger PFO devices. Interventional treatment was successfully performed on all patients. The effective occlusion rate in group I at 12 months after the procedure was significantly higher than that in group II (93.7% vs. 78.6%, P < 0.05 ). The TEE results showed that 18 patients with a medium and large residual shunt at 12 months after the procedure exhibited an intradisc tunnel-like shunt. Conclusion. The Amplatzer ASD device and Amplatzer PFO device are safe for large PFO closure, but the Amplatzer ASD device has a higher effective occlusion rate. TEE plays a crucial role in the use of the Amplatzer ASD occluder for percutaneous closure of a large PFO.

Funder

Shaanxi Province Key Industry Innovation Chain (Group)-Social Development Field

Publisher

Hindawi Limited

Subject

Pharmacology (medical),Cardiology and Cardiovascular Medicine,Pharmacology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3