Influence of Pilocarpine Eyedrops on the Ocular Biometric Parameters and Intraocular Lens Power Calculation

Author:

Gao Ruxin12ORCID,Liu Jinkun12ORCID,Zhou Xiaojie12ORCID,Huang Luping12ORCID,Huang Weiyi12ORCID,Xue Yingying12ORCID,Wang Fei12ORCID,Gong Songjian12ORCID,Wu Renyi12ORCID,Wang Yuhong12ORCID

Affiliation:

1. Department of Ophthalmology, Eye Institute & Affiliated Xiamen Eye Center, School of Medicine, Xiamen University, Xiamen 361001, China

2. Department of Ophthalmology, Fujian Provincial Key Laboratory of Corneal & Ocular Surface Diseases, Xiamen 361001, China

Abstract

Objective. To evaluate the influence of pilocarpine eyedrops on the ocular biometric parameters and whether these parameter changes affect the intraocular lens (IOL) power calculation in patients with primary angle-closure glaucoma (PACG). Methods. Twenty-two PACG patients and fifteen normal subjects were enrolled. Ocular biometric parameters including the axial length (AL), anterior chamber depth (ACD), lens thickness (LT), mean keratometry (Km), and white-to-white distance (WTW) were measured by using a Lenstar LS 900 device before and at least 30 minutes after instillation of 2% pilocarpine eyedrops. Lens position (LP) was calculated, and the IOL power prediction based on the ocular biometric parameters was performed using the Barrett Universal II, Haigis, Hoffer Q, Holladay I, or SRK/T formulas before and after pilocarpine application. Results. In both PACG and normal groups, pilocarpine eyedrops induced a slight but statistically significant increase in the mean AL (0.01 mm for both groups) and mean LT (0.02 mm and 0.03 mm, respectively) but a significant decrease in the mean ACD (0.03 mm and 0.05 mm, respectively) and mean LP (0.02 mm and 0.04 mm, respectively). No significant changes in the mean Km and WTW were noticed in both groups. In addition, the IOL power calculation revealed insignificant changes before and after the pilocarpine instillation in both groups, regardless of the formula used. Conclusions. Pilocarpine eyedrops can induce slight changes in the ocular biometric parameters including the AL, ACD, LT, and LP. However, these parameter changes will not result in a significant difference in IOL power estimation.

Funder

Natural Science Foundation of Fujian Province

Publisher

Hindawi Limited

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3