Comparison of Acceptable Noise Level Generated Using Different Transducers and Response Modes

Author:

Xia Liang1,He Jingchun2,Sun Yuanyuan1,Chen Yi1,Luo Qiong1,Shi Haibo1ORCID,Feng Yanmei1ORCID,Yin Shankai1ORCID

Affiliation:

1. Department of Otolaryngology, Shanghai Jiao Tong University Affiliated Sixth People’s Hospital, No. 600, Yishan Road, Xuhui District, Shanghai 200233, China

2. Department of Otolaryngology, Shanghai Jiao Tong University Affiliated Xinhua Hospital, No. 1665, Kongjiang Road, Yangpu District, Shanghai 200092, China

Abstract

The acceptable noise level (ANL) was defined by subtracting the background noise level (BNL) from the most comfortable listening level (MCL) (ANL = MCL − BNL). This study compared the ANL obtained through different methods in 20 Chinese subjects with normal hearing. ANL was tested with Mandarin speech materials using a loudspeaker or earphones, with each subject tested by himself or by the audiologist. The presentation and response modes were as follows: (1) loudspeaker with self-adjusted noise levels using audiometer controls (LS method); (2) loudspeaker with the subject signaling the audiologist to adjust speech and noise levels (LA method); (3) earphones with self-adjusted noise levels using audiometer controls (ES method); and (4) earphones with the subject signaling the audiologist to adjust speech and noise levels (EA method). ANL was calculated from three measurements with each method. There was no significant difference in the ANL obtained through different presentation modes or response modes sound. The correlations between ANL, MCL, and BNL obtained from each two methods were significant. In conclusion, the ANL in normal-hearing Mandarin listeners may not be affected by presentation modes such as a loudspeaker or earphones nor is it affected by self-adjusted or audiologist-adjusted response modes. Earphone audiometry is as reliable as sound field audiometry and provides an easy and convenient way to measure ANL.

Funder

Three-year Action Program on Promotion of Clinical Skills/Clinical Innovation for Municipal Hospitals

Publisher

Hindawi Limited

Subject

Clinical Neurology,Neurology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Performance of older normal-hearing listeners on the tracking of noise tolerance (TNT) test;International Journal of Audiology;2023-06-19

2. The Impact of Transducer Selection on the Acceptable Noise Level;Journal of the American Academy of Audiology;2022-01