Automated closed-loop versus standard manual oxygen administration after major abdominal or thoracic surgery: an international multicentre randomised controlled study

Author:

L'Her ErwanORCID,Jaber Samir,Verzilli Daniel,Jacob Christophe,Huiban Brigitte,Futier Emmanuel,Kerforne Thomas,Pateau Victoire,Bouchard Pierre-Alexandre,Consigny Maëlys,Lellouche François

Abstract

IntroductionHypoxaemia and hyperoxaemia may occur after surgery, with related complications. This multicentre randomised trial evaluated the impact of automated closed-loop oxygen administration after high-risk abdominal or thoracic surgeries in terms of optimising the oxygen saturation measured by pulse oximetry time within target range.MethodsAfter extubation, patients with an intermediate to high risk of post-operative pulmonary complications were randomised to “standard” or “automated” closed-loop oxygen administration. The primary outcome was the percentage of time within the oxygenation range, during a 3-day frame. The secondary outcomes were the time with hypoxaemia and hyperoxaemia under oxygen.ResultsAmong the 200 patients, time within range was higher in the automated group, both initially (≤3 h; 91.4±13.7% versus 40.2±35.1% of time, difference +51.0% (95% CI −42.8–59.2%); p<0.0001) and during the 3-day period (94.0±11.3% versus 62.1±23.3% of time, difference +31.9% (95% CI 26.3–37.4%); p<0.0001). Periods of hypoxaemia were reduced in the automated group (≤3 days; 32.6±57.8 min (1.2±1.9%) versus 370.5±594.3 min (5.0±11.2%), difference −10.2% (95% CI −13.9–−6.6%); p<0.0001), as well as hyperoxaemia under oxygen (≤3 days; 5.1±10.9 min (4.8±11.2%) versus 177.9±277.2 min (27.0±23.8%), difference −22.0% (95% CI −27.6–−16.4%); p<0.0001). Kaplan–Meier analysis depicted a significant difference in terms of hypoxaemia (p=0.01) and severe hypoxaemia (p=0.0003) occurrence between groups in favour of the automated group. 25 patients experienced hypoxaemia for >10% of the entire monitoring time during the 3 days within the standard group, as compared to the automated group (p<0.0001).ConclusionAutomated closed-loop oxygen administration promotes greater time within the oxygenation target, as compared to standard manual administration, thus reducing the occurrence of hypoxaemia and hyperoxaemia.

Funder

PHRC Inter-Régional HUGO

Publisher

European Respiratory Society (ERS)

Subject

Pulmonary and Respiratory Medicine

Reference63 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3