Affiliation:
1. School of Basic Medical Sciences, Wenzhou Medical University, Wenzhou, Zhejiang325035, China
2. School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou, China
Abstract
Objective:
Difenidol is widely used in clinical practice due to its good anti-dizziness effect
and low side effect rate. This aim was to develop an ultra-high performance liquid chromatography-
tandem mass spectrometry (UPLC-MS/MS) method for the selective and straightforward
measurement of diphenidol in mouse plasma.
Methods:
A total of eighteen mice were divided into three groups: six for intravenous administration
at a dose of 0.2 mg/kg, six for oral administration at a dose of 0.4 mg/kg, and another six for
oral administration at a dose of 1.6 mg/kg. The analytes were extracted using acetonitrile-mediated
protein precipitation following the addition of the internal standard (IS), midazolam. On an Acquity
HSS T3 column (50 mm × 2.1 mm, 1.8 μm). The quantification process involved the use of
multiple reactions monitoring (MRM) mode, with target fragment ions m/z 310.2→128.9 for
diphenidol and m/z 326.2→291.4 for IS.
Results:
For diphenidol, calibration curves showed a linear distribution between 0.2 and 50
ng/mL. The accuracy of the method was between 94.6% and 110.4%, and the mean recovery of
diphenidol in mouse plasma was over 76.5%. The intra-day and inter-day precision RSDs were
both limited to 14%. The bioavailability of diphenidol in mice was determined to be 19.9% and
23.56% for the oral dose of 0.4 mg/kg and 1.6 mg/kg, respectively.
Conclusion:
The UPLC-MS/MS was successfully applied to study the pharmacokinetics of
diphenidol in mice, to which it was administered orally and intravenously.
Publisher
Bentham Science Publishers Ltd.