Author:
Waldman G.L,Vaidyanathan T.K,Vaidyanathan J
Abstract
The purpose of this study was to compare the microleakage and tissue-adhesive interface morphology from Class V restorations using different systems of dentin adhesives. Class V cavities were prepared on buccal surfaces of 27 extracted caries-free molars and premolars. Teeth were randomly assigned to one of three groups: (1) Prime & Bond NT, a 5th generation system using an initial step of total etch followed by a second step of application of a self bonding primer (2) Clearfil SE Bond, a 5th generation adhesive system employing two separate steps of self-etch priming and subsequent bonding (3) One-up Bond F, a 6th generation one step self-etching, self-priming and self-bonding adhesive. Microleakage and interface morphology of teeth restored with these adhesives and a composite resin were evaluated. Kruskal-Wallis Test (p = 0.05) was used to analyze the results. SEM analysis was used to relate interface morphology to microleakage. The mean and (SD) values of microleakage were: Prime and Bond NT: 0.15 (0.33), Clearfil SE Bond: 0.06 (0.17) and One-up Bond F: 2.96 (0.63). The mean microleakage for One-up Bond was significantly higher than for the other groups (p<0.05). Protruding tags in dentin channels were observed in Prime and Bond and Clearfil systems, but not in One-up Bond. The single step adhesive system, although more convenient for the clinician, uses a low viscosity formulation difficult to keep in place on cavity walls. It also tends to be too aggressive and hydrophilic to create an impermeable hybridized tissue-adhesive interfacial layer resistant to microleakage. Two-step adhesive systems, on the other hand, were retained on all segments of the cavosurface during application, and formed a hybridized interfacial layer resistant to microleakage.
Publisher
Bentham Science Publishers Ltd.
Reference38 articles.
1. Bounocore MG.
A simple method of increasing the adhesion of acrylic filling materials to enamel surfaces
J Dent Res
1955;
34
: 849-53.
2. Jensen ME, Chan DC.
Polymerization shrinkage and microleakage In: Vanherle G, Smith DC, Eds.
International symposium on posterior resin dental restorative materials.
Ultrect, The Netherlands: Peter Szulc Publishing Co 2003; pp.
243-62.
3. Kugel G, Ferrari M.
The science of Bonding: From first to sixth generation
J Am Dent Assoc
2000;
131
(Suppl)
: 20-5.
4. Al-Ehaideb A, Hohammed H.
Microleakage of “One Bottle” dentin adhesives
Oper Dent
2001;
26
: 172-5.
5. Product brochure for One-Up Bond F System In:
J Morita USA Inc.
Cited by
16 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献