Dynamic Volume Computed Tomography for Characterizing Pulsatile Tinnitus Caused by Sigmoid Sinus Diverticulum with Bone Defects: Clinical Implications

Author:

Pan Yu-Ning1,Li Ai-Jing2,Zhang Jie1,Mao Quan-Liang3,Shen Fang-Jie1

Affiliation:

1. Department of Radiology, Ningbo First Hospital, Ningbo Hospital, Zhejiang University, Ningbo, Zhejiang 315010, China

2. Department of Radiology, Hwa Mei Hospital, University of Chinese Academy of Sciences, Ningbo Institute of Life and Health Industry University of Chinese Academy of Sciences, Ningbo, Zhejiang 315010, China

3. Department of Medical College, Ningbo University, Ningbo, Zhejiang, 315010, China

Abstract

Objective: The objective of this study is to investigate the diagnosis of dynamic volume computed tomography (CT) for pulsatile tinnitus caused by sigmoid sinus diverticulum (SSD) and bone defects. Methods: Data obtained by dynamic volume CT from 35 patients with SSD were retrospectively collected. Then the ear morphological parameters, including bone defect, transverse sinus stenosis, position of the jugular bulb, jugular bulb diverticulum, defect of the jugular bulb wall, gross venous sinus thrombosis and SSD, and blood perfusion parameters, including cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT), were evaluated and compared between the tinnitus side and the asymptomatic side of the ear. Results: The maximum diameters of the bone defects on the tinnitus side were greater than those on the asymptomatic side (Horizontal 6.36±2.35mm vs. 1.12±0.78mm; Longitudinal 4.87±1.25 vs. 0.88±0.06mm). Dynamic volume CT visually displayed the SSD herniated into the adjacent mastoid via the bone defect. Transverse sinus stenosis, high position of the jugular bulb, jugular bulb diverticulum, defect of the jugular bulb wall, and gross venous sinus thrombosis were present more frequently on the tinnitus side than on the asymptomatic side (P < 0.05). Moreover, CBF, CBV, and MTT were significantly greater on the tinnitus side than on the asymptomatic side (P < 0.05). Conclusion: Dynamic volume CT examination is an effective method for the diagnosis of pulsatile tinnitus caused by SSD with bone defects.

Funder

Medical and Health Technology Program in Zhejiang Province

Publisher

Bentham Science Publishers Ltd.

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3