Optimizing Prostate Imaging Practices in Saudi Arabian Hospitals: A Comprehensive Analysis of PI-RADS Compliance in Multiparametric MRI

Author:

Alshuhri Mohammed S.1,Alhulail Ahmad A.1,Alqahtani Abdullalh G. M.1,Madkhali Yahia2,Alshehri Abdullah M.3,Alghuraybi Rakan A.4,Alqahtani Saeed5ORCID,BinMhusien Meshari Ali6,Alqahtani Mansour5,Qaisi Abdulrahman7

Affiliation:

1. Radiology and Medical Imaging Department, College of Applied Medical Sciences, Prince Sattam Bin Abdulaziz University, P.O. Box 422, Alkharj 11942, Saudi Arabia

2. Department of Diagnostic Radiography Technology, College of Applied Medical Sciences, Jazan University, Jazan, Saudi Arabia

3. King Abdullah Bin Abdulaziz University Hospital, Riyadh, Saudi Arabia

4. Department of Radiology, Security Forces Hospital, Mecca, Saudi Arabia

5. Department of Radiological Sciences, College of Applied Medical Sciences, Najran University, Najran P.O. Box 1988, Saudi Arabia

6. Department of Radiology, Prince Sultan Military Medical City, Riyadh, Saudi Arabia

7. Radiology Department, Security Forces Hospital, Riyadh, Kingdom of Saudi Arabia

Abstract

Background: Prostate cancer, a significant contributor to male cancer mortality globally, demands improved diagnostic strategies. In Saudi Arabia, where the incidence is expected to double, this study assessed the compliance of multiparametric MRI (mpMRI) practices with Prostate Imaging-Reporting and Data System version 2 (PI-RADS v2) guidelines across diverse healthcare institutions. Methods: A survey was distributed to the radiology departments of all tertiary referral hospitals in Saudi Arabia (n=60) to assess their compliance with the technical specifications outlined in PI-RADS v2. Statistical analysis included chi-square, Fisher exact, ANOVA, and Student t-tests to examine the collected data; Results: The study revealed an overall commendable compliance rate of 95.23%. However, significant variations were observed in technical parameters, particularly between 1.5 Tesla and 3 Tesla scanners and tertiary versus non-tertiary hospitals. Notable adherence in certain sequences contrasted with discrepancies in T2-weighted and diffusion-weighted imaging parameters Conclusion: These findings underscore the need for nuanced approaches to optimize prostate imaging protocols, considering field strength and institutional differences. The study contributes to the ongoing refinement of standardized mpMRI practices, aiming to enhance diagnostic accuracy and improve clinical outcomes in prostate cancer.

Publisher

Bentham Science Publishers Ltd.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3