Abstract
The body of previous literature relating to the pressure loss characteristics of woven wire gauzes fails to provide adequate information on the separate effects of Reynolds number and Mach number in the range of usual interest for duct flow experiments. For this reason, tests have been carried out on a selection of eight single gauzes placed normal to the axis of a duct, of sizes (wire diameter and mesh) such as might be commonly used to give values of porosity between 0·3 and 0·7. Pressure loss measurements were carefully made, and covered independently duct Mach numbers up to choking and a 50-fold range of Reynolds number. The test data are presented so as to provide a single relation between the incompressible loss factor and a form of Reynolds number, plus a compressibility correction which depends on gauze porosity.
Cited by
97 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献