A comparison of axial length measurement by using applanation A- Scan and IOL master for accuracy of predicting postoperative refraction

Author:

Trivedi Harish R1ORCID,Zala Bhavik C2,Pancholi Nitesh S

Affiliation:

1. Government Medical College, Bhavnagar, Gujarat, India

2. G

Abstract

The higher cost of IOL master is an issue in developing countries and hence it cannot be widely used for calculation of IOL power in such countries. Thus, the aim of the current study is to evaluate a cheaper alternative for the calculation of IOL power by comparing the axial length measurement obtained using applanation A-scan with that of IOL Master for accuracy of predicting postoperative refraction.A prospective, randomized, comparative study was done with 100 patients who were posted for cataract surgery. The patients were randomly divided into two groups of 50 patients each using computerized random number method. In Group A (n=50) axial length was measured with applanation A-scan and in Group B (n=50) axial length was measured with IOL Master. Before cataract surgery keratometry reading was taken with auto keratometer and intraocular lens (IOL) power calculation was done using SRK 2 formula in all patients. All patients were operated for cataract surgery by phacoemulsification and foldable intraocular lens were implanted in the bag. Postoperatively, best accepted refraction at 8th week was taken and mean spherical equivalent was calculated. 100 patients of cataract were subjected for cataract surgery by phacoemulsification.Corrected spherical equivalent on 8th postoperative week showed: 88% patients in Group A and 96% patients of Group B were within ± 1.00 D.56% patients of Group A and 76% patients of Group B were within ± 0.50 D.There was no statistically significant difference (p > 0.05) in axial length and corrected spherical equivalent between the two groups. There is no extra advantage of IOL Master over applanation A-scan for measuring Axial Length between 21 and 24.50 and predicting post-operative refractive outcome.

Publisher

IP Innovative Publication Pvt Ltd

Subject

General Medicine

Reference12 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3