A comparative study of hemodynamic stability through intraoperative fluid administration guided by stroke volume variation assessment versus conventional parameters in terms of inferior vena cava diameter and collapsibility index during spine surgery

Author:

Ghosh Soumik1ORCID,Mukhopadhyay Salini2

Affiliation:

1. Institute of Medical Sciences, Varanasi, Uttar Pradesh, India

2. I

Abstract

Stroke volume variation (SVV) is a naturally occurring phenomenon, often used by anesthesiologists for hemodynamic response to intra-operative fluid administration. In a mechanically ventilated patient under general anesthesia, the arterial pulse pressure rises during inspiration and falls during expiration due to changes in intra-thoracic pressure secondary to positive pressure ventilation. : In this open labelled, parallel group, randomized controlled trial, we investigated the role of using SVV as a marker for optimal intra-operative fluid therapy versus the conventional parameters of hemodynamic monitoring i.e., blood pressure, pulse rate and urine output in patients undergoing major spinal surgery in prone position. It was a single centre study and each group consisted of 35 patients in the age group of 18 – 50 years having ASA grade I status and without any previous comorbidities. SVV was maintained between 10 to 13% and Non-Invasive Blood Pressure (NIBP) and pulse rate maintained within 20% of baseline pre-induction values. Ringer’s lactate solution was chosen as fluid therapy in both groups. : The study showed that the total amount of fluid infused to either group had no statistically significant difference; however, the change in Inferior vena cava maximum diameter (IVCmax) in patients of the SVV monitored group was significantly lower than the conventional arm, for a given amount of fluid in either group. (Levene’s test for equality of variance F = 45.46, test statistics for equality of means t = 3.86; p = 0.001) Moreover, those patients who were maintained on lower margin of SVV range had a remarkable decrease of collapsibility index of IVC compared to pre-operative values. (Spearman’s rank correlation r = 0.533; p = 0.001) Thus, SVV proves to be a surrogate marker of administering intravenous fluid per-operatively maintaining euvolemic status as reflected by subsequent IVC collapsibility index (CI) values obtained in patients undergoing spinal surgery.

Publisher

IP Innovative Publication Pvt Ltd

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3