Clinical assessment of awake endotracheal intubation using the lightwand technique alone in patients with difficult airways

Author:

XUE Fu-shan,HE Nong,LIAO Xu,XU Xiu-Zheng,XU Ya-chao,YANG Quan-yong,LUO Mao-ping,ZHANG Yan-ming

Abstract

Background There is few study to determine whether the use of the lightwand technique alone could achieve effective, safe and successful awake endotracheal intubation (ETI), therefore we designed a prospective clinical study to systematically evaluate the feasibility, safety and efficacy of awake ETI using the lightwand alone in patients with difficult airways. Methods Seventy adult patients with difficult airways were enrolled in this study. After the desired sedation with fentanyl and midazolam, airway topical anesthesia was performed with 9 ml of 2% lidocaine, which were in order sprayed in three aliquots at 5 minutes intervals into the supraglottic (two doses) and laryngotracheal areas (one dose) using a combined unit of the lightwand and MADgic® atomizer. After airway topical anesthesia, awake ETI was performed using a Lightwand. Subjective assessments by patients and operators using the visual analogue scores (VAS), and objective assessments by an independent investigator using patients' tolerance and reaction scores, coughing severity, intubating conditions and cardiovascular variables were taken as the observed parameters. Results Of 210 airway sprays, 197 (93.8%) were successfully completed on the first attempt. The total time for airway spray was (14.6±1.5) minutes. During airway topical anesthesia, the average patients' tolerance scores were 1.7–2.3. After airway topical anesthesia, the mean VAS for discomfort levels that the patients reported was 6.5. Also airway topical anesthesia procedure was rated as acceptable and no discomfort by 94.3% of patients. The lightwand-guided awake ETI was successfully completed on first attempt within 29 seconds in all patients. During awake ETI, patients' reaction and coughing scores were 1.9 and 1.6, respectively. All patients exhibited excellent or acceptable intubating conditions. Cardiovascular monitoring revealed that changes of systolic blood pressure and heart rate at each stage of airway manipulations were less than 20% of baseline values. The postoperative follow-up showed that 95.7% of patients had no recall or slight memories of all airway instrumentation. The incidence of postoperative mild airway complications was 38.6%. Conclusion Alone use of the lightwand technique can achieve effective, safe and successful awake ETI in patients with difficult airways.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Medicine

Reference32 articles.

1. Lighted stylet tracheal intubation: a review.;Davis;Anesth Analg,2000

2. Lightwand intubation using the TrachlightTM: a brief review of current knowledge.;Agro;Can J Anaesth,2001

3. Lightwand intubation: II-Clinical trial of a new ligthwand for tracheal intubation in patients with difficult airways.;Hung;Can J Anesth,1995

4. Intubation by use of the light wand: experience in 253 patients.;Weis;J Oral Maxillofac Surg,1989

5. Lightwand-assisted nasotracheal intubation in awake ankylosing spondylitis.;Uakritdathikarn;J Med Assoc Thai,2006

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3