Diagnostic value of endobronchial ultrasound-guided transbronchial needle aspiration in intrapulmonary lesions

Author:

ZHAO Hui,XIE Zhen,ZHOU Zu-Li,SUI Xi-Zhao,WANG Jun

Abstract

Background Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is considered to have high value in the staging of mediastinal lymph nodes in lung cancer. The current study was conducted to investigate the diagnostic value of EBUS-TBNA in intrapulmonary lesions located near the central airway. Methods From September 2009 to March 2013, 66 patients with pulmonary masses located close to the central airways suspected to be lung cancer were accessed by EBUS-TBNA. Conventional bronchoscopic biopsy before EBUS-TBNA was nondiagnostic in all cases. If EBUS-TBNA did not result in a formal pathological diagnosis of malignancy, patients were subsequently referred for a surgical procedure. Results Among the 66 cases, 59 were confirmed as pulmonary malignancies by EBUS-TBNA, of which 48 cases were non-small cell lung cancer, nine were small cell lung cancer, and two were metastatic lung tumors. No evidence of malignancy was found by biopsy and histopathological examination in the other seven cases. Thoracoscopy or thoracotomy was subsequently undergone for them. Postoperative pathological examinations confirmed three cases of squamous cell carcinoma of the lung, one case of lymphoma, two cases of sclerosing hemangioma, and one case of pulmonary tuberculoma. The definitive diagnosis rate of EBUS-TBNA for intrapulmonary lesions near the central airway was 89.4%. The sensitivity, specificity, and accuracy of EBUS-TBNA in distinguishing benign from malignant intrapulmonary lesions were 93.7%, 100.0%, and 93.9%, respectively. The positive and negative predictive values were 100.0% and 42.9%, respectively. The EBUS-TBNA procedures were well-tolerated by all patients. No associated complications were observed. Conclusions For intrapulmonary lesions near the central airway highly suspected of cancer, EBUS-TBNA has satisfactory diagnostic value. However, the negative predictive value of this technique is low, so negative results obtained by EBUS-TBNA should be confirmed by other methods.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Cited by 20 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3