Bronchial provocation test measured by using the forced oscillation technique to assess airway responsiveness

Author:

Xu Hui,Gao Yi,Xie Yanqing,Liang Xiaolin,Zheng Jinping

Abstract

Background: The bronchial provocation test (BPT) performed by using the forced oscillation technique (FOT) is cooperated without forced expiratory effort. However, a comparison of the application value and safety of BPTs measured by using the FOT and the standardized dosimeter method is lacking, which limits its clinical practice. Objective: We aimed to analyze the diagnostic value and safety of the BPT as measured by the FOT in patients with asthma and in healthy subjects. Methods: This was a randomized cross-over clinical study. Airway responsiveness was measured by using the FOT and the aerosol provocation system (APS) dosimeter method in all the participants. The between-test interval was 24 hours. The diagnostic value and safety of the two tests were analyzed. Results: Asthma control status was assessed based on ACT scores, and patients with asthma (including 27 uncontrolled, 34 partially controlled, and 32 controlled) were collected, and 69 healthy subjects were recruited. Receiver operating characteristic curves revealed slightly superior screening capability of cumulative dose of methacholine causing a 20% decrease (PD20)‐forced expiratory volume in the first second of expiration when measured by using the APS-dosimeter method (area under the curve [AUC] 0.981 [95% confidence interval {CI}, 0.952‐1.000]) over that of cumulative dose of inhaled methacholine at the inflection point when respiratory resistance began to increase continuously (Dmin) by using the FOT (AUC 0.959 [95% CI, 0.924‐0.994]). The sensitivity and specificity were 98.9% and 98.6%, respectively, with the APS-dosimeter method, and 100% and 87.0%, respectively, with the FOT. It took an average of 9.0 minutes (range, 6.0‐11.0 minutes) when using the FOT and an average of 17.0 minutes (range, 14.0‐25.0 minutes) when using APS-dosimeter method (p < 0.01) in all the participants. The measurement time for the FOT was reduced by 47.1% than the APS-dosimeter. The incidence rate of the adverse events with the FOT was slightly higher than that with the APS-dosimeter method (p < 0.05). Both tests were well tolerated. No serious adverse event was found. Conclusion: The FOT, characterized as being simple, safe, and time saving, could be used to assess airway hyperresponsiveness in patients with asthma and worthy of clinical application.

Publisher

Oceanside Publications Inc.

Subject

Pulmonary and Respiratory Medicine,General Medicine,Immunology and Allergy

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3