Affiliation:
1. Division of Preventive and Sports Medicine, Institute of Occupational, Social and Environmental Medicine, Goethe-University Frankfurt/Main, Goethe University, Frankfurt, GERMANY
2. Medical Department Eintracht Frankfurt, Frankfurt/Main, GERMANY
3. Department of Sports Medicine and Exercise Physiology, Goethe University Frankfurt/Main, GERMANY
Abstract
ABSTRACT
Introduction
Agility and cognitive skills are essential in sports. However, standardized agility assessment tools often lack a reactive component, and cognitive assessments are performed using computer-based or paper-pencil tests. The SKILLCOURT is a newly developed testing and training device allowing agility and cognitive assessments in a more ecologically valid setting. This study evaluated the reliability and sensitivity to changes in performance (usefulness) of the SKILLCOURT technology.
Methods
In a test–retest (7 d, 3 months) design, 27 healthy adults (♀ = 12; age, 24.9 ± 3.3 yr) performed three trials of agility (Star Run, Random Star Run) and motor–cognitive tests (1-back, 2-back, executive function). Absolute and relative intersession and intrasession reliability was determined using the intraclass coefficient (ICC) and coefficient of variation (CV). A repeated-measures ANOVA was applied to identify potential learning effects between trials and test sessions. The smallest worthwhile change and typical error (TE) were calculated to investigate the intrasession and intersession usefulness of the tests.
Results
Agility tests revealed good relative and absolute intersession (ICC, 83–0.89; CV, 2.7%–4.1%) and intrasession (ICC, 7–0.84; CV, 2.4%–5.5%) reliability accompanied by adequate usefulness from test day 3 onward. Motor–cognitive tests showed good relative intersession reliability (ICC, 0.7–0.77) with marginal CV values (4.8%–8.6%). Adequate intrasession reliability and usefulness can be assumed from test day 2 (1-back test, executive function test) and day 3 (2-back test) onward. For all tests, learning effects were observed within and compared with test day 1.
Conclusions
The SKILLCOURT is a reliable diagnostic tool for assessing reactive agility and motor–cognitive performance. Because of learning effects, sufficient familiarization with the tests is required when used for diagnostic purposes.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine
Reference29 articles.
1. Effect of neurocognition and concussion on musculoskeletal injury risk;Curr Sports Med Rep,2015
2. Basic cognitive abilities relevant to male adolescents’ soccer performance;Percept Mot Skills,2020
3. Attention, working-memory control, working-memory capacity, and sport performance: the moderating role of athletic expertise;Eur J Sport Sci,2021
4. Executive functions predict the success of top-soccer players;PLoS One,2012
5. Reliability, factorial validity, and interrelationships of five commonly used change of direction speed tests;Scand J Med Sci Sports,2014
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献