Longitudinal cardiac dimensions in patients undergoing LVAD implantation

Author:

Meissner Florian1ORCID,Szvetics Sophie1,Galbas Michelle Costa1,Russe Maximilian2,Schibilsky David1ORCID,Kaier Klaus3,Czerny Martin1,Bothe Wolfgang1

Affiliation:

1. Department of Cardiovascular Surgery, Heart Center Freiburg, Faculty of Medicine University of Freiburg Freiburg Germany

2. Department of Diagnostic and Interventional Radiology, Faculty of Medicine University of Freiburg Freiburg Germany

3. Institute of Medical Biometry and Statistics, Faculty of Medicine University of Freiburg Freiburg Germany

Abstract

AbstractBackgroundIn conventional left ventricular assist devices (LVAD), a separate outflow graft is sutured to the ascending aorta. Novel device designs may include a transventricular outflow cannula crossing the aortic valve (AV). While transversal ventricular dimensions are well investigated in patients with severe heart failure, little is known about the longitudinal dimensions. These dimensions are, however, particularly critical for the design and development of mechanical circulatory support (MCS) devices with transaortic outflow cannula.MethodsIn an explorative retrospective cohort study at the University Medical Center Freiburg, Germany, the longitudinal cardiac dimensions of patients undergoing computed tomography angiography (CTA) before and, if available, after LVAD implantation were analyzed. Among others, the following dimensions were assessed: (a) apex to AV, (b) apex to mitral valve, (c) AV to sinotubular junction (STJ), (d) apex to STJ, (e) apex to brachiocephalic artery (BCA), and (f) AV to BCA.ResultsIn total, 44 LVAD patients (36 male, age 55.8 years, height 1.75 m) were included. The longitudinal cardiac dimensions were (a) 114.5 ± 12.1 mm, (b) 108.0 ± 12.4 mm, (c) 20.9 ± 2.9, (d) 135.4 ± 13.4 mm, (e) 206.0 ± 18.3, and (f) 91.5 ± 9.8 mm. Postoperatively, (a) and (b) decreased by 31.5% and 39.5%, respectively (N = 14).ConclusionsLongitudinal cardiac dimensions may be reduced by up to 40% after LVAD implantation. A better knowledge of these dimensions and their postoperative alterations in LVAD patients may improve surgical planning and help to design MCS devices with transventricular outflow cannula.

Funder

Bundesministerium für Bildung und Forschung

Publisher

Wiley

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3