Diagnostic accuracy of community optometrists for age‐related macular degeneration using colour fundus photographs: A pilot evaluation

Author:

Ho Sharon12ORCID,Doig Gordon S.3ORCID,Ly Angelica2ORCID

Affiliation:

1. Centre for Eye Health The University of New South Wales Sydney New South Wales Australia

2. School of Optometry and Vision Science The University of New South Wales Sydney New South Wales Australia

3. Faculty of Medicine and Health The University of Sydney Sydney New South Wales Australia

Abstract

AbstractPurposeThe accurate diagnosis of age‐related macular degeneration (AMD) represents an important step in delaying and preventing vision loss and achieving optimal patient care. Therefore, this pilot study aimed to estimate the diagnostic accuracy of community optometrists for identifying AMD using colour fundus photographs (CFPs) to support sample size calculations for subsequent definitive studies.MethodsFive practising community optometrists were invited to classify a total of 1023 CFPs for the (1) presence of AMD, and, if applicable, (2) stage of AMD (early/intermediate/late geographic atrophy/late neovascular AMD). Diagnosis by referral centre clinicians formed the reference standard. Diagnostic accuracy was assessed by the area under the receiver operating characteristic curve (aROC). Sensitivity, specificity, positive and negative predictive values were also calculated.ResultsOf the 1023 CFPs included in the study, 226 images were of AMD and 797 images were of other ocular conditions or no abnormal findings. Participating community optometrists had a mean (SD) age of 30.2 (8.9) years, 60.0% (3/5) were female and the mean number of years practising in primary eye care was 5.4 (5.4) years. Community optometrists demonstrated excellent performance for diagnosing AMD, with an aROC of 0.86 (95% CI 0.83 to 0.89), sensitivity of 84.5% (95% CI 79.1 to 89.0) and specificity of 88.0% (95% CI 85.5 to 90.1). The aROC (95% CI) for diagnosing early, intermediate, late geographic atrophy and late neovascular AMD was 0.82 (0.73 to 0.91), 0.76 (0.72 to 0.81), 0.69 (0.49 to 0.90) and 0.55 (0.34 to 0.75), respectively.ConclusionsThese results justify the need for an appropriately powered definitive study to assess community clinicians' diagnostic accuracy for AMD.

Publisher

Wiley

Subject

Sensory Systems,Optometry,Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3