Patient and physician radiation exposure during minimally invasive lumbar decompression: A prospective assessment of X‐ray exposure risks

Author:

Mekhail Nagy1ORCID,Topalsky Krista2,Templeton Erin1,Armanyous Sherif1,Prayson Nicholas1ORCID,Olde Carl1,Costandi Shrif1ORCID

Affiliation:

1. Pain Management Department Cleveland Clinic Cleveland Ohio USA

2. Internal Medicine Department University Hospital Cleveland Ohio USA

Abstract

AbstractIntroductionMinimally invasive lumbar decompression (mild®) is becoming a popular procedure for treating lumbar spinal stenosis (LSS) secondary to hypertrophic ligamentum flavum (LF). The mild® procedure is commonly performed under live fluoroscopic guidance and carries a risk of radiation exposure to the patient and healthcare.MethodsOne physician performed mild® on 41 patients at the Cleveland Clinic Department of Pain Management from October 2019 to December 2021, while wearing a radiation exposure monitor (Mirion Technologies). Mean fluoroscopy time, mean exposure per case, and mean exposure per unilateral level decompressed were the primary outcomes measured. The secondary outcome was to provide a comparison of radiation exposure during similar fluoroscopically guided procedures.ResultsMean patient fluoroscopy exposure time was 2.1 min ±0.9 (range: 1.1–5.6) fluoroscopy time per unilateral level decompressed. The mean patient radiation skin exposure from mild® was 1.1 ± 0.9 mGym2, and the mean total dose was 142.3 ± 108.6 mGy per procedure. On average, the physician was exposed to an average deep tissue exposure of 4.1 ± 3.2 mRem, 2.9 ± 2.2 mRem estimated eye exposure, and 14.7 ± 11.0 mRem shallow tissue exposure per unilateral level decompressed. An individual physician would exceed the annual exposure limit of 5 Rem after approximately 610 mild® procedures per year.ConclusionsThis study is an attempt to quantify the radiation exposure to the physician and patient during the mild® procedure. Compared with other fluoroscopically guided pain management procedures, patient and physician radiation exposure during mild® was low.

Publisher

Wiley

Subject

Anesthesiology and Pain Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3