Implant efficiency and clinical performance of Aveir™ VR and Micra™ VR leadless pacemaker: A multicenter comparative analysis of 67 patients

Author:

Tokavanich Nithi12ORCID,Machado Christian3,Banga Sandeep12,Smiles Katelyn12,Dhar Anya4,Ali Abbas5,Ali Mohammed5,Qutrio Baloch Zulfiqar12,Ip John12

Affiliation:

1. Thoracic and Cardiovascular Institute Sparrow Hospital Lansing Michigan USA

2. Sparrow Clinical Research Institute Lansing Michigan USA

3. Department of Cardiology Ascension Providence Hospital Southfield Michigan USA

4. Department of Chemistry University of Michigan Ann Arbor Michigan USA

5. Heart and Vascular Institute West Virginia University Medicine Morgantown West Virginia USA

Abstract

AbstractIntroductionLeadless pacemaker (LP) is a novel pacemaker that has been proven to be effective and safe; however, the majority of LPs in previous reports were the Medtronic Micra™ VR LP. We aim to evaluate the implant efficiency and clinical performance of the Aveir™ VR LP compared to the Micra™ VR LP.MethodWe performed a retrospective analysis in two healthcare systems (Sparrow Hospital and Ascension Health System, Michigan) in patients implanted with LPs between January 1, 2018, and April 1, 2022. The parameters were collected at implantation, 3 months and 6 months.ResultsA total of 67 patients were included in the study. The Micra™ VR group had shorter time in the electrophysiology lab (41 ± 12 vs. 55 ± 11.5 min, p = .008) and shorter fluoroscopic time (6.5 ± 2.2 vs. 11.5 ± 4.5 min, p < .001) compared to the Aveir™ VR group. The Aveir™ VR group had a significantly higher implant pacing threshold compared to the Micra™ VR group (0.74 ± 0.34 mA vs. 0.5 ± 0.18 mA at pulse width 0.4 ms, p < .001), but no difference was found at 3 months and 6 months. There was no significant difference in the R‐wave sensing and impedance and pacing percentage at implantation, 3 months, and 6 months. Complications of the procedure were rare. The mean projected longevity of the Aveir™ VR group was longer than the Micra™ VR group (18.8 ± 4.3 vs. 7.7 ± 0.75 years, p < .001).ConclusionImplantation of the Aveir™ VR required longer laboratory and fluoroscopic time, but showed longer longevity at 6 months follow‐up, compare to the Micra™ VR. Complications and lead dislodgement are rare.

Publisher

Wiley

Subject

Cardiology and Cardiovascular Medicine,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献